Stylet slow-pull vs. standard suction technique for endoscopic ultrasound-guided fine needle biopsy in pancreatic solid lesions using 20 Gauge Procore™ needle: A multicenter randomized trial

Volume: 52, Issue: 2, Pages: 178 - 184
Published: Feb 1, 2020
Abstract
Background Standard suction and slow-pull techniques have been utilized during endoscopic ultrasound-guided fine needle aspiration of pancreatic solid lesions, but the correct sampling technique remains unclear. New needles designed to obtain samples suitable for histological evaluation have become available. We performed a study comparing the two sampling methods during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in patients with...
Paper Details
Title
Stylet slow-pull vs. standard suction technique for endoscopic ultrasound-guided fine needle biopsy in pancreatic solid lesions using 20 Gauge Procore™ needle: A multicenter randomized trial
Published Date
Feb 1, 2020
Volume
52
Issue
2
Pages
178 - 184
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.