Review paper

Failure analysis of boiler tube at a petrochemical plant

Volume: 106, Pages: 104146 - 104146
Published: Dec 1, 2019
Abstract
This research aims to assess the failure analysis of a boiler tube of a steam generation system at a petrochemical plant. To achieve this goal, firstly visual observation and thickness measurements were made to detect different features of failure. Secondly optical microscope and scanning electron microscope (SEM) were used observing the microstructures and also hardness measurements were carried out for metallurgical evaluation. Additionally,...
Paper Details
Title
Failure analysis of boiler tube at a petrochemical plant
Published Date
Dec 1, 2019
Volume
106
Pages
104146 - 104146
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.