Failure evaluation of SA 210C riffle water wall tubes in 70 MW CFBC boiler

Volume: 95, Pages: 239 - 247
Published: Jan 1, 2019
Abstract
Boiler tubes used as water walls made up of ferritic steels is having some finite life, because of prolonged exposure in the furnace at elevated temperature, stress and aggressive environment, tube failure taking place. Now a day's premature failure of the boiler tube mainly in water walls is one of the very common phenomena in the thermal power plants. The present investigation was done on the as-received ASTM SA 210C failed boiler tube steel...
Paper Details
Title
Failure evaluation of SA 210C riffle water wall tubes in 70 MW CFBC boiler
Published Date
Jan 1, 2019
Volume
95
Pages
239 - 247