Complications of appendicular fracture repair in cats and small dogs using locking compression plates

Published on Oct 29, 2015in Veterinary and Comparative Orthopaedics and Traumatology0.877
· DOI :10.3415/VCOT-14-09-0146
Rosario Vallefuoco5
Estimated H-index: 5
,
Helene Le Pommellet1
Estimated H-index: 1
+ 5 AuthorsPascal Fayolle6
Estimated H-index: 6
Sources
Abstract
Objective: Our objectives were: 1) to review the complications associated with stabilization of appendicular fractures in cats and small dogs using locking compression plates (LCP), and 2) to identify factors that could influence fixation construct stability. Study design: Retrospective clinical study. Materials and methods: Medical and radiographic records of cats and small dogs with appendicular fractures treated with LCP were reviewed. Only cases with adequate follow-up to document clinical union and cases for which complications appeared before the clinical union were included. Complications were classified as implant-related complications or other complications. Cases with implant-related complications were compared to cases with non-implant-related complications for differences in signalment (species, age, body weight, multiple fractures), fracture location and type (fractured bone, fracture localization, closed or open fracture), reduction method (open reduction and internal fixation [ORIF] or minimally invasive plate osteosynthesis [MIPO]) and fixation evaluations (implant size, plate-bridging ratio, plate span ratio, working length, plate screw density, number of screws and cortices engaged per plate and per main fragment, ratio between screw and bone diameter at the narrowest aspect of the bone, and presence of ancillary fixation). Results: Seventy-five fractures from 63 cats (64 fractures) and 10 dogs (11 fractures) met the inclusion criteria. Eight humeral, 13 radio-ulnar, 26 femoral, and 28 tibio-fibular fractures were treated. Primary repair of the fracture was performed using 2.0 mm and 2.4 mm LCP in 22 and 53 fractures, respectively. Overall and implant-related complications were encountered in 13 and seven of 75 fractures, respectively. Fixation failure was not significantly associated with any aforementioned factor considered in this study, and in particular, there was no significant difference in the occurrence of fixation failure between fractures stabilized with two, or more than two, bicortical locking screws per main fragment. Clinical significance: 2.0 mm and 2.4 mm LCP were used to manage appendicular fractures in cats and small dogs. The overall complication and fixation failure rate were comparable to those reported in previous studies in which various locking plate systems were used.
📖 Papers frequently viewed together
18 Citations
1 Citations
References21
Newest
#1Tomás G. GuerreroH-Index: 10
#2Karin KalchofnerH-Index: 8
Last. Patrick R Kircher (UZH: University of Zurich)H-Index: 16
view all 4 authors...
OBJECTIVE: To evaluate use of the Advanced Locking Plate System (ALPS) in dogs and cats and report outcome. STUDY DESIGN: Retrospective case series. ANIMALS: Dogs (n 09= 0929) and cats (n 09= 0942). METHODS: The medical records (April 2007-April 2010) of dogs and cats treated with ALPS were reviewed evaluated. Data retrieved included signalment, indication for surgery, complications, and outcome. RESULTS: ALPS was used for 54 fractures, 12 tarsal or carpal ligament injuries and in 6 cases, to pr...
16 CitationsSource
#1Peini Chao (UF: University of Florida)H-Index: 3
#2Bryan P. Conrad (UF: University of Florida)H-Index: 28
Last. Antonio Pozzi (UF: University of Florida)H-Index: 25
view all 5 authors...
Background There are several factors that can affect the fatigue life of a bone plate, including the mechanical properties of the plate and the complexity of the fracture. The position of the screws can influence construct stiffness, plate strain and cyclic fatigue of the implants. Studies have not investigated these variables in implants utilized for long bone fracture fixation in dogs and cats. The purpose of the present study was to evaluate the effect of plate working length on construct sti...
37 CitationsSource
#1Stephen Q Garofolo (UF: University of Florida)H-Index: 1
#2Antonio Pozzi (UF: University of Florida)H-Index: 25
Objective To (1) evaluate the normal extraosseous blood supply of the cranial aspect of the canine radius and (2) to compare the effects of minimally invasive (MIPO) and open plating technique on its preservation. Study Design Experimental cadaveric study. Sample Population Adult canine thoracic limbs (n = 36) obtained from cadavers weighing 25–35 kg. Methods Twelve unpaired limbs were used to study the normal extraosseous blood supply. Each limb was injected with blue latex and India ink, and t...
18 CitationsSource
#1Antonio Pozzi (UF: University of Florida)H-Index: 25
#2Caleb C. Hudson (UF: University of Florida)H-Index: 6
Last. Daniel Lewis (UF: University of Florida)H-Index: 31
view all 4 authors...
Objective To compare the efficacy of reduction, time to union, and clinical outcome of radius and ulna fractures stabilized using either minimally invasive plate osteosynthesis (MIPO) or open reduction and internal fixation (ORIF). Study Design Retrospective, case-controlled study. Animals Dogs with radius and ulna fractures stabilized with plates applied using MIPO (n = 15) or ORIF (n = 15). Methods Dogs in each stabilization group were matched for type and location of fracture, age, and body w...
37 CitationsSource
#2Cristobal F. RidesH-Index: 1
Last. Steven J. Naber (OSU: Ohio State University)H-Index: 6
view all 12 authors...
(PAX) Matthew D. Barnhart1, DVM MS Diplomate ACVS, Cristobal F. Rides2, DVM, Shawn C. Kennedy1, DVM Diplomate ACVS, Sean W. Aiken3, DVM MS Diplomate ACVS, Charles M. Walls4, DVM Diplomate ACVS, Christopher L. Horstman5, DVM MS Diplomate ACVS, David Mason5, B. Vet. Med MRCVS, Diplomate ACVS & ECVS, Jonathon C. Chandler6, DVM MS Diplomate ACVS, Jeff D. Brourman6, DVM MS Diplomate ACVS, Sean M. Murphy6, DVM Diplomate ACVS, Frederick Pike3, DVM Diplomate ACVS, and Steven J. Naber7, MS PhD
18 CitationsSource
Objectives: To retrospectively evaluate the stabilization of appendicular fractures in dogs using the Fixin locking plate system.Materials and methods: Medical records and radiographs of dogs with fractures stabilized with the Fixin system in the period from May 2005 to September 2010 were reviewed. For each patient, data pertaining to signalment, the nature of the fracture, implants used, and evidence of fracture healing were recorded. The outcome and complications were determined from clinical...
17 CitationsSource
#1Antonio Pozzi (UF: University of Florida)H-Index: 25
#2Marije RisseladaH-Index: 10
Last. Matthew D. WinterH-Index: 11
view all 3 authors...
Objective—To evaluate fracture healing after minimally invasive plate osteosynthesis (MIPO) or open reduction and internal fixation (ORIF) of coexisting radius and ulna fractures in dogs via ultrasonography and radiography. Design—Prospective cohort study. Animals—16 dogs with radius-ulna fractures that underwent MIPO (n = 9; 2 dogs were subsequently not included in the analyses because of incomplete follow-up information) or ORIF (7). Procedures—Dogs in the 2 treatment groups were matched by ag...
34 CitationsSource
Objectives: To compare fracture healing in diaphyseal tibial fractures stabilized using either minimally invasive plate osteosynthesis (MIPO) or open reduction and internal fixation (ORIF). Methods: Dogs in each group were matched for type of fracture, age and body weight. Stage of healing was measured blindly every four weeks postoperatively until complete healing. Outcome variables including fracture length, plate length, plate bridging ratio, plate working length, healing grading, and fractur...
30 CitationsSource
#1Konrad L. HoffmeierH-Index: 13
#2Gunther O. HofmannH-Index: 33
Last. Thomas MückleyH-Index: 30
view all 3 authors...
Abstract Background It is hypothesized that the working length influences the implants fatigue behavior. However, few studies addressing this issue came to contrary results. Therefore, we tested systematically the influence of working length and implant material on the plate's endurance. Methods We used an artificial model providing the substantial angle and length conditions of a human femur. A fracture gap of 10 mm was bridged with identical shaped plate implants made of stainless steel and gr...
43 CitationsSource
#1Laurent P. Guiot (MSU: Michigan State University)H-Index: 8
#2Loïc M. Déjardin (MSU: Michigan State University)H-Index: 17
OBJECTIVE: To evaluate the clinical outcome of minimally invasive plate osteosynthesis (MIPO) for nonarticular tibial fractures stabilized using bone plates with or without an intramedullary rod (IMR). STUDY DESIGN: Prospective study. ANIMALS: Dogs (n=28) and 8 cats. METHODS: After closed reduction, fracture fixation was achieved using an epiperiosteal plate inserted percutaneously through epiphyseal small incisions. In some fractures, an IMR was inserted via medial parapatellar arthrotomy. Radi...
62 CitationsSource
Cited By14
Newest
#1Dayvid Vianêis Farias de Lucena (UNESP: Sao Paulo State University)
#2Bruno Watanabe Minto (UNESP: Sao Paulo State University)H-Index: 10
Last. Luis Gustavo Gosuen Gonçalves Dias (UNESP: Sao Paulo State University)H-Index: 5
view all 6 authors...
Interlockings nails (IN) are orthopedic implants with superior mechanical and, potentially, biological qualities. Despite the countless and indisputable advantages of current angle-stable models, there are still limitations for their use in certain scenarios. The objective of the present study was to describe and biomechanically test a new orthogonal angle-stable intramedullary nail model for veterinary use. The proposed orthogonal angle-stable nail has two 3.8-mm threaded cylindrical holes in e...
Source
#1Danielle M. Marturello (MSU: Michigan State University)H-Index: 2
#2Karen L Perry (MSU: Michigan State University)H-Index: 10
Last. Loïc M. Déjardin (MSU: Michigan State University)H-Index: 17
view all 3 authors...
OBJECTIVE To describe medium-term functional outcome after nail osteosynthesis in feline traumatology and report clinically relevant recommendations for I-Loc angle-stable interlocking nail use in cats. STUDY DESIGN Prospective clinical study. SAMPLE POPULATION Client-owned cats (n = 29). METHODS Consecutive cases with femoral, tibial, or humeral fractures were included. Outcome measures included fracture and surgical procedure description, limb alignment, nail size vs body weight (BW), percenta...
Source
#1Jean BassaninoH-Index: 2
#2Jakub Kaczmarek (Augsburg College)H-Index: 1
Last. Dimitri LeperlierH-Index: 5
view all 10 authors...
OBJECTIVE To report radiographic findings and complications after fracture repair with a new polyaxial locking plate system (PLS polyaxial locking system; Aesculap/B Braun, Tuttlingen, Germany) in dogs and cats. STUDY DESIGN Retrospective case review from four veterinary practices. SAMPLE POPULATION Twenty-six dogs and 14 cats (40 long bone fractures). METHODS Medical and radiographic records of dogs and cats with long bone fractures treated with the PLS were reviewed. Cases were included when o...
Source
#1Guy Bird (Murdoch University)
#2Mark Glyde (Murdoch University)H-Index: 9
Last. Robert E. Day (RPH: Royal Perth Hospital)H-Index: 23
view all 5 authors...
Objective: This investigation compared the biomechanical properties of a 2.0 mm locking compression notched head T-plate (NHTP) and 2.0 mm straight locking compression plate (LCP), in a simple transverse juxta-articular fracture model. Study Design: Two different screw configurations were compared for the NHTP and LCP, modelling short (configuration 1) and long working length (configuration 2). Constructs were tested in compression, perpendicular and tension non-destructive four point bending an...
Source
Objective The aim of this study was to retrospectively evaluate the clinical application of the Fixin mini 1.9 to 2.5 system for the treatment of long bone fractures in cats. We proposed that the Fixin mini system would successfully stabilize long bone fractures in cats with a healing time and complication rate similar to those previously reported for feline fractures using other locking bone plate systems. Materials and Methods Medical records and radiographs of cats with long bone fractures st...
Source
#1Guy Bird (Murdoch University)
#2Mark Glyde (Murdoch University)H-Index: 9
Last. Robert E. Day (RPH: Royal Perth Hospital)H-Index: 23
view all 5 authors...
Objective This investigation compared the biomechanical properties of a 2.0 mm locking compression notched head T-plate (NHTP) and 2.0 mm straight locking compression plate (LCP), in a compressed, short, juxta-articular fragment fracture model. Methods Two different screw configurations were compared for the NHTP and LCP, modelling short (configuration 1) and long working length (configuration 2). Constructs were tested in compression, perpendicular and tension four-point bending and torsion. Pl...
Source
#1Francesco Piana (UoB: University of Bristol)H-Index: 1
#2Miguel A. SolanoH-Index: 7
Last. Russell YeadonH-Index: 13
view all 4 authors...
OBJECTIVE: The aim of this study was to document application of locking plates for stabilization of acetabular fractures along with complications and clinical outcomes. We hypothesized that complications and clinical outcomes would be comparable to historical reports using non-locking plate and screw constructs. STUDY DESIGN: Medical records of dogs presented with acetabular fractures at a single referral centre between 2010 and 2018 were reviewed. Cases surgically managed by open reduction and ...
1 CitationsSource
#1Danielle M. Marturello (MSU: Michigan State University)H-Index: 2
#2Dirsko J. F. von Pfeil (MSU: Michigan State University)H-Index: 7
Last. Loïc M. Déjardin (MSU: Michigan State University)H-Index: 17
view all 3 authors...
OBJECTIVE: To compare the torsional behavior of two small angle-stable interlocking nails (I-Loc and Targon) with that of locking compression plates (LCP). To evaluate the effect of implant removal on the torsional strength of feline bone surrogates. STUDY DESIGN: Experimental. SAMPLE POPULATION: Fracture gap constructs and intact explanted bone surrogates. METHODS: Fracture gap constructs were stabilized with one of six implants (I-Loc 3 and 4, Targon 2.5 and 3.0, LCP 2.0 and 2.4) and then cycl...
2 CitationsSource
#1Matthew R. FieldH-Index: 1
#2Ryan Butler (MSU: Mississippi State University)H-Index: 4
Last. Wilburn M. MaxwellH-Index: 1
view all 4 authors...
Background Internal plate fixation and, more recently, locking plate fixation are commonly used in the repair of fractures in small animal surgery. This retrospective study reviewed the use of the String of Pearls locking plate system in the fixation/repair of appendicular long bone skeleton fractures in 31 small animal veterinary patients (33 fractures).
1 CitationsSource
#1Luis Gustavo Gosuen Gonçalves Dias (UNESP: Sao Paulo State University)H-Index: 5
#2João Guilherme Padilha Filho (UNESP: Sao Paulo State University)H-Index: 7
Last. Virginia T. Barbosa (UNESP: Sao Paulo State University)
view all 5 authors...
Setor de Cirurgia Veterinaria Departamento de Clinica e Cirurgia Animal Faculdade de Ciencias Agrarias e Veterinarias (FCAV) Universidade Estadual Paulista Julio de Mesquita Filho (Unesp), Via de Acesso Prof. Paulo Donato Castellane s/n
Source