This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the chamber design, including the cavity length, the mass density of the wall material, and the size of the central electrode, in addition to the cavity radius. Moreover, the effective point of measurement also depends on the beam quality and the field size. The paper therefore argues that the upstream shift of 0.6 times the cavity radius, recommended in current dosimetry protocols, is inadequate for accurate relative photon beam dosimetry, particularly in the build-up region. On the other hand, once the effective point of measurement is selected appropriately, measured depth-ionization curves can be equated to measured depth-dose curves for all depths within ± 0.5 % .
📖 Papers frequently viewed together
1 Author (Iwan Kawrakow)
3 Authors (M. R. McEwen, ..., Carl K. Ross)
References24
Newest
#1Elena TonkopiH-Index: 8
#2M. R. McEwenH-Index: 8
Last. Iwan KawrakowH-Index: 37
view all 4 authors...
This article presents an investigation of the influence of the ion chamber response, including buildup caps, on the measurement of in-air off-axis ratio (OAR) profiles in megavoltage photon beams using Monte Carlo simulations with the EGSnrc system. Two new techniques for the calculation of OAR profiles are presented. Results of the Monte Carlo simulations are compared to measurements performed in 6, 10 and 25 MV photon beams produced by an Elekta Precise linac and shown to agree within the expe...
Source
#3Chien-Chung Chen (TMU: Taipei Medical University)H-Index: 30
Purposes: To verify the output factors (OFs) of Gamma Knife Model B2 by various conventional dosimeters and to determine an effective correction factor for compensating the dosimeter sizes. Method and Materials: The TLDs, radiochromic films, PTW 31002 ion chamber and the diamond detector were used to obtain the OFs, normalized to the 18 mm helmet, for four helmets. The factors were measured in the centre of an 80 mm polystyrene spherical phantom that was positioned at the mechanical center of th...
Source
#1W Abdel‐Rahman (MUHC: McGill University Health Centre)H-Index: 5
#2Jan Seuntjens (MUHC: McGill University Health Centre)H-Index: 52
Last. Ervin B. Podgorsak (MUHC: McGill University Health Centre)H-Index: 18
view all 5 authors...
Recent work has shown that there is significant uncertainty in measuring build-up doses in megavoltage photon beams especially at high energies. In this present investigation we used a phantom-embedded extrapolation chamber (PEEC) made of Solid Water{sup TM} to validate Monte Carlo (MC)-calculated doses in the dose build-up region for 6 and 18 MV x-ray beams. The study showed that the percentage depth ionizations (PDIs) obtained from measurements are higher than the percentage depth doses (PDDs)...
Source
#1Iwan Kawrakow (National Research Council)H-Index: 37
#2David W. O. Rogers (National Research Council)H-Index: 61
Last. B. R. B. Walters (National Research Council)H-Index: 7
view all 3 authors...
The introduction into the BEAMnrc code of a new variance reduction technique, called directional bremsstrahlung splitting (DBS), is described. DBS uses a combination of interaction splitting for bremsstrahlung, annihilation, Compton scattering, pair production and photoabsorption, and Russian Roulette to achieve a much better efficiency of photon beam treatment head simulations compared to the splitting techniques already available in BEAMnrc (selective bremsstrahlung splitting, SBS, and uniform...
Source
#1Omar Chibani (VCU: Virginia Commonwealth University)H-Index: 4
#2Chang Ming Charlie Ma (Fox Chase Cancer Center)H-Index: 5
The dose from photon-induced nuclear particles (neutrons,protons, and alpha particles)generated by high-energy photonbeams from medical linacs is investigated. Monte Carlo calculations using the MCNPX code are performed for three different photonbeams from two different machines: Siemens 18 MV, Varian 15 MV, and Varian 18 MV. The linac head components are simulated in detail. The dose distributions from photons,neutrons,protons, and alpha particles are calculated in a tissue-equivalent phantom. ...
Source
This study investigates a possible cause of reported significant dose discrepancies between Monte Carlo calculations and measurements in the buildup region for high-energy photon beams in large fields. A proposed hypothesis was that the discrepancy was caused by a source of electrons in the accelerator head that was not fully accounted for in the treatment head simulation. In this investigation, a lead foil is added just below the accelerator head in order to study this hypothesis. The lead foil...
Source
The purpose of this study is to provide detailed characteristics of incident photon beams for different field sizes and beam energies. This information is critical to the future development of accurate treatment planning systems. It also enhances our knowledge of radiotherapy photon beams. The EGS4 Monte Carlo code, BEAM, has been used to simulate 6 and 18 MV photon beams from a Varian Clinac-2100EX accelerator. A simulated realistic beam is stored in a phase space data file, which contains deta...
Source
Source
#1C. L. Hartmann Siantar (LLNL: Lawrence Livermore National Laboratory)H-Index: 2
#2R. S. Walling (LLNL: Lawrence Livermore National Laboratory)H-Index: 1
Last. Lynn J. Verhey (UCSF: University of California, San Francisco)H-Index: 41
view all 13 authors...
PEREGRINE is a three-dimensional Monte Carlo dose calculation system written specifically for radiotherapy. This paper describes the implementation and overall dosimetric accuracy of PEREGRINE physics algorithms, beam model, and beam commissioning procedure. Particle-interaction data, tracking geometries, scoring, variance reduction, and statistical analysis are described. The BEAM code system is used to model the treatment-independent accelerator head, resulting in the identification of primary...
Source
#1Daryoush Sheikh-Bagheri (Carleton University)H-Index: 5
#2David W. O. Rogers (National Research Council)H-Index: 61
Last. Jan Seuntjens (National Research Council)H-Index: 52
view all 4 authors...
¯ /r) air variation in the phantom, calculated in an identical geometry for the realistic beams using a new EGS4 user code, SPRXYZ. The variation of ( L ¯ /r) air with depth is a 1.25% correction at 10 MV and a 2% correction at 20 MV. At both energies, the calculated and the measured values of ionization on the central axis in the buildup region agree within 1% of maximum ionization relative to the ionization at 10 cm depth. The agreement is well within statistics elsewhere. The electron contami...
Source
Cited By68
Newest
#1Sumalee Yabsantia (Chula: Chulalongkorn University)H-Index: 1
#2Sivalee Suriyapee (Chula: Chulalongkorn University)H-Index: 7
Last. Jan Seuntjens (McGill University)H-Index: 52
view all 8 authors...
Abstract null null Purpose null To determine the field output correction factors of the radiophotoluminescence glass dosimeter (RPLGD) in parallel and perpendicular orientations with reference to CC01, the ionization chamber. null null null Methods null The dose to a small water volume and the sensitive volume of the RPLGD and the IBA-CC01 were determined for 6-MV, 100-cm SAD, 10-cm depth using egs_chamber user-code. The RPLGD in perpendicular and parallel orientations to the beam axis were stud...
Source
#1V. Giménez-Alventosa (Polytechnic University of Valencia)H-Index: 3
#2V Gimenez (CSIC: Spanish National Research Council)H-Index: 1
Last. Pedro AndreoH-Index: 43
view all 5 authors...
: The beam quality correction factor kQfor megavoltage photon beams has been calculated for eight PTW (Freiburg, Germany) ionization chambers (Farmer chambers PTW30010, PTW30011, PTW30012, and PTW30013, Semiflex 3D chambers PTW31021, PTW31010, and PTW31013, and the PinPoint 3D chamber PTW31016). Simulations performed on the widely used NE-2571 ionization chamber have been used to benchmark the results. The Monte Carlo code PENELOPE/penEasy was used to calculate the absorbed dose to a point in wa...
Source
Three different correction factors for measurements with the parallel-plate ionization chamber PTW T34013 on the Esteya electronic brachytherapy unit have been investigated. This chamber type is recommended by AAPM TG-253 for depth-dose measurements in the 69.5 kV x-ray beam generated by the Esteya unit. Monte Carlo simulations using the PENELOPE-2018 system were performed to determine the absorbed dose deposited in water and in the chamber sensitive volume at different depths with a Type A unce...
Source
#1Sonja Wegener (University of Würzburg)H-Index: 5
#2Otto A. Sauer (University of Würzburg)H-Index: 13
PURPOSE: The effective point of measurement (EPOM) of cylindrical ionization chambers differs from their geometric center. The exact shift depends on chamber construction details, above all the chamber size, and to some degree on the field-size and beam quality. It generally decreases as the chamber dimensions get smaller. In this work, effective points of measurement in small photon fields of a range of cylindrical chambers of different sizes are investigated, including small chambers that have...
Source
#1Björn DelfsH-Index: 7
#2Ralf-Peter Kapsch (German National Metrology Institute)H-Index: 11
Last. Björn PoppeH-Index: 21
view all 6 authors...
Abstract The frequently applied narrow and non-standard transverse dose profiles of intensity modulated photon-beam radiotherapy, lacking lateral secondary electron equilibrium, require the use of high-resolution dosimetry detectors, and small air-filled detectors are recommended as the reference detectors for cross-calibration of the high-resolution detectors. The present study focuses on the dosimetric properties of a novel cylindrical ionization chamber, the PTW Semiflex 3D 31021. The chamber...
Source
#1M Lawless (UW: University of Wisconsin-Madison)H-Index: 3
#2Lianna D. DiMaso (UW: University of Wisconsin-Madison)H-Index: 1
Last. Larry A. DeWerd (UW: University of Wisconsin-Madison)H-Index: 20
view all 6 authors...
PURPOSE: This work seeks to investigate new methods to determine the absorbed dose to water from kilovoltage x rays. Current methods are based on measurements in air and rely on correction factors in order to account for differences between the photon spectrum in air and at depth in phantom, between the photon spectra of the calibration beam and the beam of interest, or in the radiation absorption properties of air and water. This work aims to determine the absorbed dose to water in the NIST-mat...
Source
#2Vicente Blanca Giménez (CSIC: Spanish National Research Council)H-Index: 2
Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'la...
Source
#1D. J. O'Brien (University of Texas MD Anderson Cancer Center)H-Index: 7
#2J. DolanH-Index: 2
Last. Gabriel O. SawakuchiH-Index: 23
view all 5 authors...
Purpose The purpose of this study was to acquire beam data for an MR-linac, with and without a 1.5 T magnetic field, by using a variety of commercially available detectors to assess their relative response in the magnetic field. The impact of the magnetic field on the measured dose distribution was also assessed. Methods An MR-safe 3D scanning water phantom was used to measure output factors, depth dose curves, and off-axis profiles for various depths and for field sizes between 2 × 2 cm2 and 22...
Source
#1Peter G. F. Watson (McGill University)H-Index: 5
#2Marija PopovicH-Index: 3
Last. Jan SeuntjensH-Index: 52
view all 3 authors...
Electronic brachytherapy sources are widely accepted as alternatives to radionuclide-based systems. Yet, formal dosimetry standards for these devices to independently complement the dose protocol provided by the manufacturer are lacking. This article presents a formalism for calculating and independently verifying the absorbed dose to water from a kV x-ray source (The INTRABEAM System) measured in a water phantom with an ionization chamber calibrated in terms of air-kerma. This formalism uses a ...
Source
#1E Simiele (UW: University of Wisconsin-Madison)H-Index: 3
#2Blake R. Smith (UW: University of Wisconsin-Madison)H-Index: 8
Last. Wesley S. Culberson (UW: University of Wisconsin-Madison)H-Index: 10
view all 3 authors...
Abstract Purpose A commercial plastic scintillation detector was used to determine the effective point of measurement (EPOM) of three cylindrical ionization chambers in four clinical electron beams. The experimentally determined EPOM values were compared to Monte Carlo (MC)-calculated EPOM values from the literature. The energy dependence of the EPOM was also investigated. Methods Percent depth dose (PDD) curves were measured with an Exradin W1 scintillation detector and were used as a represent...
Source