Accurate measurement of the transmitral gradient in patients with mitral stenosis: A simultaneous catheterization and Doppler echocardiographic study

Published on Jul 1, 1994in Journal of the American College of Cardiology20.589
· DOI :10.1016/0735-1097(94)90556-8
Rick A. Nishimura128
Estimated H-index: 128
(Mayo Clinic),
Charanjit S. Rihal96
Estimated H-index: 96
(Mayo Clinic)
+ 1 AuthorsDavid R. Holmes192
Estimated H-index: 192
(Mayo Clinic)
Sources
Abstract
Abstract Objectives . This study compared the accuracy of Doppler echocardiography with that of conventional cardiac catheterization in the measurement of transmitral gradients in patients with mitral stenosis. Background . Simultaneous measurement of left atrial and left ventricular pressures is the most accurate method for determination of the mean mitral valve gradient in patients with mitral stenosis. Because of the inherent risks of transseptal catheterization, pulmonary capillary wedge pressure has been used in many invasive laboratories for determination of the mean mitral valve gradient. Recent studies have observed significant errors when pulmonary capillary wedge pressure was used for these measurements. Doppler echocardiography provides a noninvasive alternative for measurement of the transmitral gradient, but its relative accuracy has remained unclear. Methods . Seventeen patients with mitral stenosis who underwent transseptal cardiac catheterization had simultaneous measurement of 1) transmitral gradient by direct left atrial and left ventricular pressures, 2) transmitral gradient by pulmonary capillary wedge and left ventricular pressures, and 3) transmitral gradient by Doppler echocardiography. Results . Transmitral gradient measured by pulmonary capillary wedge and left ventricular pressures significantly overestimated the gradient obtained by direct measurement of left atrial pressure, with a mean (±SD) difference of 3.3 ± 3.5 mm Hg (or 53%). Correcting the pulmonary capillary wedge pressure for the phase shift resulted in better correlation, but a consistent overestimation still remained, with a mean difference of 2.5 ± 2.9 mm Hg (or 43%). The best correlation with the smallest variability was comparison of the Doppler-derived mean gradient with the gradient from direct measurement of left atrial and left ventricular pressures, with a mean difference of 0.2 ± 1.2 mm Hg. Conclusions . Compared with the transmitral gradient obtained by direct measurement of left atrial and left ventricular pressures, the Doppler-derived gradient is more accurate than that obtained by conventional cardiac catheterization and should be considered the reference standard.
📖 Papers frequently viewed together
198823.60Circulation
233 Citations
197923.60Circulation
3 Authors (L Hatle, ..., A Tromsdal)
596 Citations
198823.60Circulation
204 Citations
References34
Newest
#1Jarle HolenH-Index: 5
#2Rune AaslidH-Index: 2
Last. Svein SimonsenH-Index: 51
view all 4 authors...
A 2 MHz continuous waveform noninvasive ultrasound doppler system has been used in the present investigation. With the aid of the audio signals of the frequency shifts, the ultrasound probe was positioned on the external chest so that the axis of the incident ultrasonic beam coincided with the direction of the maximum velocity vectors of the mitral jet. The frequency shifts due to the mitral jet were frequency analyzed and the time course of the maximum frequency shift was determined. The time c...
431 CitationsSource
#1Rick A. Nishimura (Mayo Clinic)H-Index: 128
#2R. S. Schwartz (Mayo Clinic)H-Index: 5
Last. David R. Holmes (Mayo Clinic)H-Index: 192
view all 4 authors...
BACKGROUNDThe instantaneous pressure gradient between the left ventricle and left atrium during systole can be calculated from the mitral regurgitation Doppler velocity curve. The purpose of our study was to determine the accuracy of measuring the time constant of relaxation (TAU) derived from the Doppler mitral regurgitation signal by comparing it with simultaneous high-fidelity left ventricular pressure measurements in humans.METHODS AND RESULTSTwenty-five patients had continuous-wave Doppler ...
84 CitationsSource
#1Darryl J. Burstow (Mayo Clinic)H-Index: 28
#2Rick A. Nishimura (Mayo Clinic)H-Index: 128
Last. Abdul J. Tajik (Mayo Clinic)H-Index: 62
view all 7 authors...
Studies correlating prosthetic valve gradients determined by continuous wave Doppler echocardiography with gradients obtained by cardiac catheterization have, to date, been limited to patients with mitral and tricuspid prostheses or have compared nonsimultaneous measurements. Simultaneous Doppler and catheter pressure gradients in 36 patients (mean age, 63 +/- 13 years) with 42 prosthetic valves (20 aortic, 20 mitral, one tricuspid, and one pulmonary) were studied. Catheter gradients were obtain...
146 CitationsSource
#1Richard A. Lange (UTSW: University of Texas Southwestern Medical Center)H-Index: 69
#1Richard A. Lange (UTSW: University of Texas Southwestern Medical Center)H-Index: 37
Last. L. David Hillis (UTSW: University of Texas Southwestern Medical Center)H-Index: 65
view all 4 authors...
There is disagreement concerning the use of the pulmonary capillary wedge pressure (in place of left atrial pressure) in assessing the presence and severity of mitral valve disease. This study was done to assess the accuracy and reliability of an oximetrically confirmed pulmonary capillary wedge pressure in measuring the transvalvular pressure gradient and valve area in patients with mitral stenosis. In 10 patients with mitral stenosis (1 man and 9 women; mean age ± SD 47 ± 7 years), pulmonary c...
55 CitationsSource
#1Joseph S. Alpert (UMMS: University of Massachusetts Medical School)H-Index: 107
15 CitationsSource
#1J M Bland (St George's Hospital)H-Index: 88
#2Douglas G. Altman (St George's Hospital)H-Index: 268
Abstract In clinical measurement comparison of a new measurement technique with an established one is often needed to see whether they agree sufficiently for the new to replace the old. Such investigations are often analysed inappropriately, notably by using correlation coefficients. The use of correlation is misleading. An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatabilit...
35.1k CitationsSource
In patients with symptoms of heart failure after mitral valve replacement, identification of a stenosed prosthesis may be difficult. Twelve such patients were evaluated, presenting at a mean of 8.4 years after mitral valve replacement (four mechanical, eight porcine). Trans-valvular pressure gradients were obtained using both indirect (pulmonary capillary wedge) and direct (transseptal catheterization) measurements of left atrial pressure. In all 12 patients, the diastolic gradient across the pr...
46 CitationsSource
11 CitationsSource
#1R. Brad Stamm (UVA: University of Virginia)H-Index: 5
#2Randolph P. Martin (UVA: University of Virginia)H-Index: 8
Two-dimensional echocardiography has proven very useful in assessing valvular heart disease, but the technique is limited in certain groups of patients and is unable to quantify a transvalvular pressure gradient. Advances in the Doppler ultrasound techniques have made it possible to noninvasively measure velocity of flow across a stenotic heart valve and to calculate the pressure gradient. A commercially available, continuous and pulse wave Doppler instrument was utilized to assess the transvalv...
234 CitationsSource
#1Jeffrey D. Hosenpud (OHSU: Oregon Health & Science University)H-Index: 51
#2John H. McAnulty (OHSU: Oregon Health & Science University)H-Index: 32
Last. Mark J. Morton (OHSU: Oregon Health & Science University)H-Index: 23
view all 3 authors...
We investigated the relationship between left atrial (LA) and pulmonary capillary wedge pressure (PCW) in order to define the clinical settings in which PCW may be used to approximate LA pressure and to determine the cause and significance of difference between LA and PCW pressures. Nineteen patients who at cardiac catheterization had LA, PCW, and left ventricular (LV) pressures recorded, had mitral valve gradients and areas determined. Mean PCW and LA pressures correlated well (r = 0.94). Phasi...
20 CitationsSource
Cited By107
Newest
#1William R. Miranda (Mayo Clinic)H-Index: 14
#2C. Charles Jain (Mayo Clinic)H-Index: 4
Last. Donald J. Hagler (Mayo Clinic)H-Index: 88
view all 3 authors...
Abstract Although the arterial switch operation has become the standard form of surgical repair for complete transposition of the great arteries, a large number of adults post-atrial switch are still followed in current practice. Pulmonary venous baffle obstruction is a well-known complication of the atrial switch operation, mimicking heart failure. Its recognition is important as it is a potentially treatable disease. In the past, retrograde pulmonary venous atrium (PVA)/pulmonary venous baffle...
Source
Source
#1Rim Halaby (UPenn: University of Pennsylvania)H-Index: 2
#2Howard C. Herrmann (UPenn: University of Pennsylvania)H-Index: 92
Last. Gregg W. Stone (ISMMS: Icahn School of Medicine at Mount Sinai)H-Index: 63
view all 14 authors...
OBJECTIVES The authors sought to evaluate the association between mean mitral valve gradient (MVG) and clinical outcomes among patients who underwent MitraClip treatment for secondary mitral regurgitation (SMR) in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) trial. BACKGROUND In the COAPT trial, patients with heart failure (HF) and severe SMR who remained symptomatic despite guideline-directed...
1 CitationsSource
#1Nahoko Kato (Mayo Clinic)H-Index: 3
#2Sorin V. Pislaru (Mayo Clinic)H-Index: 36
Last. Patricia A. Pellikka (Mayo Clinic)H-Index: 101
view all 7 authors...
Abstract Objectives The aims of this study were to: 1) develop a formula for projected transmitral gradient (TMG), expected gradient under normal heart rate (HR), and stroke volume (SV); and 2) assess the prognostic value of projected TMG. Background In mitral stenosis (MS), TMG is highly dependent on hemodynamics, often leading to discordance between TMG and mitral valve area. Methods All patients with suspected MS based on echocardiography from 2001 to 2017 were analyzed. Data were randomly sp...
1 CitationsSource
#1Philip C. WienerH-Index: 2
#2Ahmed Darwish (Concordia University)H-Index: 2
Last. Gregg S. PressmanH-Index: 19
view all 5 authors...
Introduction Study aims were to compare hemodynamics and viscous energy dissipation (VED) in 3D printed mitral valves-one replicating a normal valve and the other a valve with severe mitral annular calcification (MAC). Patients with severe MAC develop transmitral gradients, without the commissural fusion typifying rheumatic mitral stenosis (MS), and may have symptoms similar to classical MS. A proposed mechanism relates to VED due to disturbed blood flow through the diseased valve into the ventr...
Source
#1Catherine M OttoH-Index: 85
#2Rick A. NishimuraH-Index: 128
Last. Christopher TolyH-Index: 4
view all 15 authors...
46 CitationsSource
18 CitationsSource
#1Chisato IzumiH-Index: 21
#2Kiyoyuki Eishi (Nagasaki University)H-Index: 13
Last. Kiyoshi YoshidaH-Index: 63
view all 34 authors...
10 CitationsSource
Mitral annular calcification (MAC) is increasingly encountered, particularly among the elderly and those with chronic kidney disease, and is often associated with a transvalvular gradient. In contrast to rheumatic mitral stenosis relatively little is known about mitral stenosis due to MAC. We aimed to clarify whether exercise limitation in this group is primarily due to valvular obstruction or ventricular dysfunction resulting from multiple comorbidities. 20 patients with severe MAC (bulky calci...
Source
#1Gregg S. PressmanH-Index: 19
#2Rupesh RanjanH-Index: 2
Last. Geu Ru HongH-Index: 20
view all 5 authors...
Mitral stenosis is classically caused by rheumatic disease (RMS). However, degenerative mitral stenosis (DMS) is increasingly encountered, particularly in developed countries with aging populations. The aim of this study was to compare clinical and echocardiographic characteristics between the 2 entities. One hundred fifteen patients with DMS were identified from an echocardiographic database in the United States and compared with 510 patients with RMS from Seoul, Korea. All subjects had a mitra...
3 CitationsSource