Performance of the ReD TPC, a novel double-phase LAr detector with silicon photomultiplier readout

Volume: 81, Issue: 11
Published: Nov 1, 2021
Abstract
A double-phase argon Time Projection Chamber (TPC), with an active mass of 185 g, has been designed and constructed for the Recoil Directionality (ReD) experiment. The aim of the ReD project is to investigate the directional sensitivity of argon-based TPCs via columnar recombination to nuclear recoils in the energy range of interest (20-200 keV_{nr} for direct dark matter searches. The key novel feature of the ReD TPC is a readout system...
Paper Details
Title
Performance of the ReD TPC, a novel double-phase LAr detector with silicon photomultiplier readout
Published Date
Nov 1, 2021
Volume
81
Issue
11
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.