Monte Carlo calculation of organ dose coefficients for internal dosimetry: Results of an international intercomparison exercise

Volume: 148, Pages: 106661 - 106661
Published: Nov 1, 2021
Abstract
EURADOS Working Group 6 has organized an intercomparison exercise on the use of the ICRP Reference Computational Phantoms with radiation transport codes. This paper summarizes the results of a specific task from the intercomparison exercise modelling internal radiation sources. The quantities to be calculated were absorbed fractions and specific absorbed fractions for monoenergetic photon and electron sources as well as S-values for two...
Paper Details
Title
Monte Carlo calculation of organ dose coefficients for internal dosimetry: Results of an international intercomparison exercise
Published Date
Nov 1, 2021
Volume
148
Pages
106661 - 106661
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.