Effect of Alkaline Electrolyzed Water on Performance Improvement of Green Concrete with High Volume of Mineral Admixtures

Published on Jan 1, 2021in Journal of Renewable Materials1.341
· DOI :10.32604/JRM.2021.015398
Source
Abstract
References25
Newest
#1Yufeng Li (Shanghai Ocean University)H-Index: 3
#2Qiao-Hui Zeng (FOSU: Foshan University)H-Index: 7
Last. Jing Jing Wang (FOSU: Foshan University)H-Index: 12
view all 9 authors...
Abstract A novel protein extraction method of ultrasound-assisted basic electrolyzed water (BEW) was proposed, and its effects on the structural and functional properties of Antarctic krill proteins were investigated. Results showed that BEW reduced 30.9% (w/w) NaOH consumption for the extraction of krill proteins, and its negative redox potential (−800 ~ −900 mV) protected the active groups (carbonyl, free sulfhydryl, etc.) of the proteins from oxidation compared to deionized water (DW). Moreov...
5 CitationsSource
#1Sumit Chakraborty (University of Sheffield)
#2Romio MandalH-Index: 2
Last. Kypros PilakoutasH-Index: 33
view all 5 authors...
Abstract This work investigates the sulfate and chloride resistance of cement composites (mortar and concrete) manufactured using electrolyzed water. Control and electrolyzed water-based cement composites were prepared using distilled water and 30 min electrolyzed water, respectively. These were exposed to 5% Na2SO4, 3.5% NaCl, and a combined mixture of 5% Na2SO4 and 3.5% NaCl solution for 200 days. Additionally, rebar reinforced control and electrolyzed water-based samples were exposed to ambie...
1 CitationsSource
#1E. PrabakaranH-Index: 4
Last. M. Nithya (CMR Institute of Technology)H-Index: 2
view all 4 authors...
Abstract The most important challenge for concrete technologists is to improve the properties of concrete. The performance of the concrete in structural aspect is been taken in mind when we go for the large structures and as well as the durability which plays a major role on it. India is fast growing country with more unskilled labourers and the lack of knowledge in concrete behaviour which leads to complications in the performance of concrete. In the recent years, in India, a new technology, ca...
2 CitationsSource
#1Kaiyue Zhao (Qingdao University)H-Index: 5
#2Yun Qiao (Qingdao University)H-Index: 1
Last. Yupeng Tian (Qingdao University)H-Index: 3
view all 5 authors...
Abstract The evaporation of water from chloride-contaminated concrete during drying process causes reverse convection of chloride ions, resulting in chloride ions to accumulate on the concrete surface, thus affecting concrete durability and service life. In this contribution, the pre-dried treatment, capillary absorption test, free diffusion test, drying test were carried out to experimentally investigate the influence of diffusion and convection on chloride transport. RCM test, isothermal adsor...
38 CitationsSource
#1Jianwei Sun (THU: Tsinghua University)H-Index: 2
#2Zengqi Zhang (THU: Tsinghua University)H-Index: 12
Last. Guihua HouH-Index: 1
view all 3 authors...
Abstract Fly ash microsphere (FAM), a high value-added by-product, are powdered hollow beads separated from fly ash in power plants. This paper investigated the effects of FAM as a mineral admixture on the 3 d hydration and microstructure of cement. A composite binder containing inert quartz powder with a surface area similar to that of FAM was selected as the control sample. The results show that FAM has a low reaction degree at room temperature because FAM mainly exerts physical effects, and a...
9 CitationsSource
#1Edy Supardi (College of Health Sciences, Bahrain)H-Index: 1
#2Saldy Yusuf (Hasanuddin University)H-Index: 4
Last. Hasniati Haeruddin (College of Health Sciences, Bahrain)H-Index: 1
view all 4 authors...
Abstract Objective This study aims to evaluate the effect of electrolyzed water effect on bacterial colonization on diabetic foot ulcer (DFU) patients. Method This is an in vitro study. Eight bacteria are incubated into 5 types of electrolyzed water (ESAW), electrolyzed weak acid water (EWAW), electrolyzed neutral water (ENAW), electrolyzed weak alkaline water (EWAlW), and electrolyzed strong alkaline water (ESAlW). Evaluations were performed 2, 24, 48 and 72 h after incubation. Data were analyz...
3 CitationsSource
1 CitationsSource
#1Sanjukta SahooH-Index: 2
#2Trupti Ranjan Mahapatra (VSSUT: Veer Surendra Sai University of Technology)H-Index: 19
Last. Sanjib Jaypuria (IIT-KGP: Indian Institute of Technology Kharagpur)H-Index: 3
view all 6 authors...
Abstract Mineral admixture concrete is proved to be beneficial to enhance strength and resistance of concrete against aggressive chemical environment. However, water binder (w/b) ratio is the major responsible factor to govern all the concrete material properties. So, for a strong and durable concrete, it is imperative to design a proper mix with suitable w/b ratio. The present study investigates the effects of w/b ratio on the compressive strength and acid resistance property of mineral admixtu...
4 CitationsSource
#1Sumit Chakraborty (Indian Institute of Engineering Science and Technology, Shibpur)H-Index: 14
#2Romio Mandal (Indian Institute of Engineering Science and Technology, Shibpur)H-Index: 2
Last. Subrata Chakraborty (Indian Institute of Engineering Science and Technology, Shibpur)H-Index: 24
view all 4 authors...
Abstract The use of electrolyzed water is expected to be a unique alternative approach to early repair of structural concrete and step up the construction process. The present investigation reveals the effectiveness of electrolyzed water in controlling the physical and mechanical properties of cement mortar at the fresh and early hardened states. The mortar samples were made using distilled water and 30 min electrolyzed water to compare their properties. The effect of the electrolyzed water on t...
5 CitationsSource
#1Romio Mandal (Indian Institute of Engineering Science and Technology, Shibpur)H-Index: 2
#2Sumit Chakraborty (Indian Institute of Engineering Science and Technology, Shibpur)H-Index: 14
Last. Subrata Chakraborty (Indian Institute of Engineering Science and Technology, Shibpur)H-Index: 24
view all 4 authors...
Abstract The effect of electrolyzed water in controlling the setting behavior of cement paste was investigated in this study. The distilled, as well as the 30 min electrolyzed water, was used to prepare the cement paste. Analyzing the results, the final setting time of control cement (CC) paste, as well as the 30 min electrolyzed water based cement (EC) paste, was measured to be 172 ± 5 min and 108 ± 4 min, respectively. The reduction of setting time is due to the quick hydration of cement clink...
5 CitationsSource
Cited By0
Newest