Abstract
This paper analyses the performance of a future planned 500 MW ultra-supercritical pulverized coal power plant. The steam cycle configuration comprises a single-stage reheat, four high pressure feedwater heaters, three low pressure feedwater heaters and the deaerator. The electricity generation unit consists of a high pressure turbine, an intermediate pressure turbine, two double-flow low pressure turbines and the electric generator. The...
Paper Details
Title
Thermodynamic analysis of a 500 MW ultra-supercritical pulverized coal power plant
Published Date
Jan 1, 2021
Volume
15
Issue
1
Pages
28 - 31