A comparison of failure assessment diagram options for Inconel 690 and Incoloy 800 nuclear steam generators tubes

Volume: 140, Pages: 107310 - 107310
Published: Jun 1, 2020
Abstract
In the context of structural integrity assessment of cracked Steam Generator Tubes (SGTs), the Failure Assessment Diagram (FAD) has been proposed as a modern tool able to reduce the conservativeness of traditional plastic limit load analyses. As different FAD failure curves are available in the literature, this paper presents a comparison between the so-called Options 1, 2 and 3 FAD curves derived for Inconel 690 and Incoloy 800 nuclear SGTs....