Citlalli Gaona
Autonomous University of Chihuahua
Silica fumePhysicsMortarCuring (chemistry)HumanitiesBond strengthComposite materialThermocoupleAbsorption of waterTafel equationFlexural strengthMetallurgyMaterials scienceMineralogyPolarization (electrochemistry)Cathodic protectionCorrosionMolten saltCarbonatationQuartzPortland cementProperties of concreteRetortGround granulated blast-furnace slagPotassiumElectrochemistrySodiumPlasticizerTernary operationPorosityDielectric spectroscopyPozzolanFly ashSlag
9Publications
2H-index
36Citations
Publications 8
Newest
#1J. García (Grupo México)H-Index: 1
#2Facundo Almeraya (Universidad Autónoma de Nuevo León)H-Index: 2
Last. J. M. Bastidas (CSIC: Spanish National Research Council)H-Index: 32
view all 9 authors...
Abstract Impressed current cathodic protection (ICCP) is a widely used method to protect steel reinforcements against corrosion. Bond degradation between concrete and steel at protection and overprotection levels was studied. Two types of materials were tested: an ordinary Portland cement (OPC) and a mixture of 85% OPC and 15% fly ash (OPC/FA). Concrete specimens were immersed in a 3.5% sodium chloride (NaCl) solution. Chemical analysis of sodium, potassium and hydrogen ions was performed using ...
14 CitationsSource
#2Facundo AlmerayaH-Index: 1
Last. Alberto MartínezH-Index: 4
view all 5 authors...
En este trabajo de investigacion se establece un sistema de conservacion de puentes de concreto reforzado, a traves de un monitoreo autonomo a distancia, instalando sensores de corrosion y transmitiendo las senales por radio modem de manera inalambrica en tiempo real, con la finalidad de corregir oportunamente los danos causados por la corrosion en ambientes marinos. El estudio se basa en una evaluacion y diagnostico completos de puentes empleando tecnicas de Mapeo de Potenciales de Corrosion (A...
#1Ricardo Velásquez (Grupo México)
#2María Acosta (Grupo México)
Last. Alberto Martínez (Grupo México)H-Index: 4
view all 5 authors...
En este trabajo se busco determinar la influencia de los aditivos en la corrosion de estructuras de concreto reforzado, empleando tecnicas electroquimicas.Se hizo la determinacion cuantitativa y cualitativa de sus propiedades (analisis quimico de aditivos, acero, pH, resistencia a compresion, flexion, porosidady absorcion), de las cantidades optimas de acuerdo a las Normas ASTM y ACI. Se evaluo el desempeno de los aditivos, se midieron potenciales yvelocidades de corrosion. Tambien se determino ...
#1María Acosta (Grupo México)
#2Ricardo Velásquez (Grupo México)
Last. Alberto Martínez (Grupo México)H-Index: 4
view all 5 authors...
La presente investigacion tuvo como objetivo principal evaluar el comportamiento de corrosion en vigas de concreto reforzado, por medio tecnicas electroquimicas como la medicion de Potenciales de Corrosion y Resistencia a la Polarizacion Lineal. Estas vigas son expuestas a ciclos de secado y saturacion en agua potable y cloruro de sodio (NaCl) al 3.5%, ya que la tecnica de Resistencia a la Polarizacion es la que actualmente se aplica para la evaluacion de estructuras de concreto reforzado asi co...
#1E.P. Reyes-DiazH-Index: 1
#2F. AlmerayH-Index: 1
Last. Facultad de IngenieríaH-Index: 1
view all 8 authors...
The main reason for the premature failure of reinforced concrete structures is corrosion of the reinforcements. The use of new mortars based on ternary mixtures, an alternative to ordinary Portland cement (OPC), requires extensive research in order to check its passivating properties for reinforcements and the instability or permanence of the passive state achieved. Pozzolans and slag extend the market for concrete by improving specific properties of concrete products, allowing them to be constr...
9 Citations
view all 6 authors...
Source
#2Facundo AlmerayaH-Index: 1
Last. Miguel BaltazarH-Index: 2
view all 5 authors...
Se estudiaron concretos adicionando ceniza volante, micro-silice y escoria de alto horno, el objetivo fue determinar cual de las mezclas presenta mejor comportamiento como proteccion contra la corrosion del acero. Se prepararon seis mezclas y se construyeron celdas de concreto donde se le adiciono el 20% con respecto al peso de aditivos, con dos varillas embebidas en la mezcla como electrodos y fueron expuestas a una solucion de NaCl (3.5% en peso), durante ocho meses se monitorearon con tecnica...
Source
#1Facundo AlmerayaH-Index: 2
Last. J. M. MaloH-Index: 1
view all 5 authors...
Many hot corrosion problems in industrial and utility boilers are caused by molten salts. The corrosion processes which occur in salts are of an electrochemical nature, and so they can be studied using electrochemical test methods. In this research, electrochemical techniques in molten salt systems have been used for the measurements of molten corrosion processes. Electrochemical test methods are described here for a salt mixture of 80%V 2 O 5 -20%Na 2 SO 4 at 540-680°C. To establish better the ...
2 CitationsSource