Shakeel A. Qureshi
Guy's and St Thomas' NHS Foundation Trust
Internal medicineRadiologyBalloonSurgeryMagnetic resonance imagingCardiologyHemodynamicsOcclusionCardiac catheterizationStentPulmonary valveAortaStenosisHeart diseaseAngiographyPercutaneousPulmonary arteryCatheterBalloon dilationMedicine
358Publications
51H-index
6,260Citations
Publications 314
Newest
#1Eric Rosenthal (Guy's and St Thomas' NHS Foundation Trust)H-Index: 66
#1Eric J. Rosenthal (Guy's and St Thomas' NHS Foundation Trust)H-Index: 2
Last. Evan M. Zahn (Cedars-Sinai Medical Center)H-Index: 34
view all 17 authors...
BACKGROUND Covered stent correction of sinus venosus ASDs (SVASD) is a relatively new technique. Challenges include anchoring a sufficiently long stent in a nonstenotic superior vena cava (SVC) and expanding the stent at the wider SVC-RA junction without obstructing the anomalous right upper pulmonary vein (RUPV). The 10-zig covered Cheatham-platinum (CCP) stent has the advantage of being available in lengths of 5-11 cm and dilatable to 34 mm in diameter. METHODS An international registry review...
Source
#1Worakan PromphanH-Index: 8
#1Worakan PromphanH-Index: 1
Last. Shakeel A. QureshiH-Index: 1
view all 2 authors...
The ductal stenting (DS) is currently an acceptable palliative treatment in newborns suffering with duct-dependent pulmonary circulation. However, this procedure remains technically a challenge in complex ductal morphology, which may eventually lead to detrimental outcomes. This review is mainly focused on pre-procedural planning, essential instruments and practical approaches for DS, and post-procedural care.
Source
#1Emma Pascall (Guy's and St Thomas' NHS Foundation Trust)
#2Matthew I. Jones (Guy's and St Thomas' NHS Foundation Trust)H-Index: 3
Last. Shakeel A. Qureshi (Guy's and St Thomas' NHS Foundation Trust)H-Index: 51
view all 5 authors...
Transcatheter creation of an interatrial communication using the Occlutech Atrial Flow Regulator Device for pulmonary hypertension or heart failure is well described. We report a case of an 8-year-old boy with a failing Fontan circulation, in whom the Atrial Flow Regulator was used to successfully create a fenestration between the pulmonary artery and left atrium, improving his clinical condition.
Source
#1Joselyn RwebemberaH-Index: 4
#2Twalib AlikuH-Index: 11
Last. Emmy Okello (MUK: Makerere University)H-Index: 18
view all 20 authors...
Background: Low- and-middle-income-countries (LMICs) currently bear 80% of the world’s cardiovascular disease (CVD) mortality burden. The same countries are underequipped to handle the disease burden due to critical shortage of resources. Functional cardiac catheterization laboratories (cath labs) are central in the diagnosis and management of CVDs. Yet, most LMICs, including Uganda, fall remarkably below the minimum recommended standards of cath lab:population ratio due to a host of factors inc...
Source
#1Asim Al Balushi (Guy's and St Thomas' NHS Foundation Trust)
#2Emma Pascall (Guy's and St Thomas' NHS Foundation Trust)
Last. Gianfranco Butera ('KCL': King's College London)H-Index: 32
view all 5 authors...
Objectives: We report our experience of using the Bentley BeGraft Aortic stent in patients with severe or near-atretic aortic coarctation and small femoral arterial access. Background: Use of covered stent is recommended in some settings such as aortic coarctation with associated aneurysm, Turner syndrome, and coarctation with aortic atresia. However, currently available covered stents need larger sheaths that may limit their use in children and patients with smaller arterial access. Newer stent...
Source
#1Oliver Bates (Guy's and St Thomas' NHS Foundation Trust)
#2Matthew I. Jones (Guy's and St Thomas' NHS Foundation Trust)H-Index: 3
Last. Gianfranco Butera ('KCL': King's College London)H-Index: 32
view all 5 authors...
Abstract Objectives To report our experience using the 10-zig C-P stents in children and adults with congenital heart disease. Background The use of stents in congenital heart disease has become widespread since the 1990s and a large range of stents has been designed for a variety of indications. In many situations there is a need for stents that can be dilated to large diameters without excessive shortening. Cheatham-Platinum (10-zig C-P) (NuMED, Hopkinton, NY, USA.) stents may fulfil this requ...
Source
#1Worakan Promphan (Rangsit University)H-Index: 8
#2Pirapat MokarapongH-Index: 2
Last. Shakeel A. Qureshi (Guy's and St Thomas' NHS Foundation Trust)H-Index: 51
view all 4 authors...
Abstract Percutaneous pulmonary valve replacement with the self-expandable Venus P-valveTM has shown satisfactory feasibility and early and mid-term outcomes. However, the long-term results are not well described. This is a report of the gross and microscopic findings of the explanted Venus P-valveTM 78 months after implantation.
Source
#1Tomohito Kogure (Guy's and St Thomas' NHS Foundation Trust)
#2Gianfranco Butera (Guy's and St Thomas' NHS Foundation Trust)H-Index: 32
Last. Shakeel A. Qureshi (Guy's and St Thomas' NHS Foundation Trust)H-Index: 51
view all 8 authors...
Abstract The use of Melody valves in the mitral position has been introduced in clinical practice. Stent fracture is a recognized complication of Melody valve implantation in the pulmonary position, however, reports in the mitral position are rare. We present the case of an 8-year-old male in whom complete fracture of the proximal stent struts occurred causing acute severe mitral stenosis and in whom urgent hybrid transapical Melody valve implantation in the fractured Melody valve was performed ...
Source
#1Federica Brancato (Guy's and St Thomas' NHS Foundation Trust)H-Index: 1
#2Eric Rosenthal (Guy's and St Thomas' NHS Foundation Trust)H-Index: 66
Last. Gianfranco Butera ('KCL': King's College London)H-Index: 32
view all 8 authors...
Abstract Superior sinus venosus atrial septal defect is a communication between the two atria located above the upper margin of the oval fossa, immediately caudal to the junction of the superior vena cava and the right atrium. Commonly, it is associated with partial anomalous pulmonary venous drainage, particularly of the right upper pulmonary vein. Surgical repair has been the gold-standard approach to close this congenital anomaly, with excellent results. However, some recent studies have show...
Source
After total correction for tetrolgy of fallot (TOF), right ventricle behaves in an unpredictable manner depending on type of right ventricular outflow tract (RVOT) reconstruction and surgical expertise of infundibular muscle resection. We are reporting a 23 years old girl who underwent total correction at two years of age. RVOT was reconstructed with native pericardial patch. Gradually she developed breathlessness and occasional chest pain. Echocardiograghy revealed hugely dilated right ventricl...
Source