The effect of crack length on SIF and elastic COD for elbow with circumferential through wall crack

Volume: 52, Issue: 9, Pages: 2092 - 2099
Published: Sep 1, 2020
Abstract
Many damages due to flow-accelerated corrosion and cracking have been observed during recent in-service inspections of nuclear power plants. To determine the operability or repair for damaged pipes, an integrity evaluation related to the damaged piping system should be performed by using already proven code and standards. One of them, the ASME Code Case is most popularly used to integrity assessment in nuclear power plants. However, the recent...
Paper Details
Title
The effect of crack length on SIF and elastic COD for elbow with circumferential through wall crack
Published Date
Sep 1, 2020
Volume
52
Issue
9
Pages
2092 - 2099
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.