IEEE Transactions on Nuclear Science
IF
1.68
Papers
22.2k
Papers 10,000
1 page of 1,000 pages (10k results)
Newest
#1H. Dewitte (University of Toulouse)H-Index: 2
#2Vincent Goiffon (University of Toulouse)H-Index: 21
Last. Philippe PailletH-Index: 15
view all 7 authors...
The paper studies the radiation effects on the junction leakage random telegraph signal (JL-RTS). Using arrays of transistors, a statistical study of the phenomenon in MOSFETs source p-n junctions is performed and the impact of the electric field, the type of irradiation, and the source design is investigated. It appears that although JL-RTS originate both from the DDD- and TID-induced defects, the latter is the dominant contribution in MOSFETs sources due to an electric field enhancement. The p...
Source
#1Tetsuichi Kishishita (Graduate University for Advanced Studies)
#2Ryoji Kosugi (AIST: National Institute of Advanced Industrial Science and Technology)H-Index: 13
Last. Yasunori Tanaka (AIST: National Institute of Advanced Industrial Science and Technology)H-Index: 16
view all 9 authors...
We report on SiC pn-junction diodes with a high blocking voltage over 3 kV. Although SiC radiation sensors have been developed with a Schottky barrier type due to a simple fabrication process in the early stages, pn junction structures are advantageous due to lower sensitivity of the surface defects. Thus, this system provides an ideal condition to investigate the effect of bulk crystal defects on the characteristics of the radiation sensor. The pn diodes were designed with a device simulator an...
Source
#1Yanan Zhang (Beihang University)
#2Min Yang (Beihang University)H-Index: 7
Last. Lin Qiang (Beihang University)H-Index: 2
view all 6 authors...
X-ray computed laminography (CL), as a popular nondestructive testing technology, has unique advantages for the detection of plate-type structures. However, with the limitation of the detector size, the specimen, i.e., large flat-like components, may be beyond the field of view (FOV) of the CL system. For the cone-beam computed tomography (CBCT) system, which is analogous to the CL system, a traditional way to enlarge the FOV is the displaced sample stage scanning mode. In this article, a new CL...
Source
Source
Source
Source
#1L. BuonannoH-Index: 5
#2Davide Di VitaH-Index: 3
Last. Carlo FioriniH-Index: 28
view all 4 authors...
Source
Source
Source
Source
12345678910
Top fields of study
This website uses cookies.
We use cookies to improve your online experience. By continuing to use our website we assume you agree to the placement of these cookies.
To learn more, you can find in our Privacy Policy.