Fatigue Loading Effect in Custom-Made All-on-4 Implants System: A 3D Finite Elements Analysis

IRBM4.80
Volume: 43, Issue: 5, Pages: 372 - 379
Published: Oct 1, 2022
Abstract
This study aims to evaluate the fatigue stress around custom-made all-on-4 implants system to find out which type of implants have a better performance under different graded multidirectional occlusal forces. 3D normal and implanted models simulating the “All-on-4” concept were created and analyzed under three different conditions of occlusal loadings. Two types of static and fatigue were applied. Stress distribution was analyzed based on von...
Paper Details
Title
Fatigue Loading Effect in Custom-Made All-on-4 Implants System: A 3D Finite Elements Analysis
Published Date
Oct 1, 2022
Journal
Volume
43
Issue
5
Pages
372 - 379
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.