Efficacy and safety of 50-60 Watt high-power short-duration radiofrequency catheter ablation of atrial fibrillation: A propensity score matching study

Volume: 23, Issue: Supplement_3
Published: May 1, 2021
Abstract
Funding Acknowledgements Type of funding sources: None. Introduction Although high-power short-duration (HPSD) radiofrequency (RF) energy is commonly utilized in atrial fibrillation (AF) catheter ablation (CA), its efficacy, safety, and autonomic neural effects have not yet been evaluated in a large patient number. We compared HPSD-AFCA and conventional power (ConvP)-AFCA after propensity score matching. Methods Among 3,221 consecutive AF...