Exploiting the performance of hyper-cross-linked polystyrene for removal of multi-component heavy metal ions from wastewaters

Volume: 9, Issue: 4, Pages: 105724 - 105724
Published: Aug 1, 2021
Abstract
In this research, Hyper-cross-linked polystyrene was used for simultaneous removal of nickel and lead ions. The necessary number of experiments and optimum values of each factor were determined using response surface methodology (RSM). The optimum value of temperature, nickel, and lead concentrations, and pH was obtained 60 ℃, 50.715 mg/L, 80 mg/L, and 7 respectively, for Ni(II) adsorption in which the nickel uptake and selectivity were...
Paper Details
Title
Exploiting the performance of hyper-cross-linked polystyrene for removal of multi-component heavy metal ions from wastewaters
Published Date
Aug 1, 2021
Volume
9
Issue
4
Pages
105724 - 105724
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.