Dissection and removal of bile duct plastic stents penetrating the duodenal papilla: report of three rare cases

Published: May 18, 2021
Abstract
We encountered three cases with incidental penetration of a straight Amsterdam-type bile duct plastic stent into the duodenal papilla. All patients had undergone insertion of a biliary plastic stent due to common bile duct stones. However, in all three cases, we observed penetration of the biliary plastic stent into the duodenal papilla just before the elective surgery or at the time of plastic stent replacement. We, therefore, performed stent...