Laparoscopic closure of the pouch of Douglas by a peritoneal running suture. A minimally invasive and prosthetic-free technique to prevent excessive dose delivery to the small bowel during pelvic irradiation for prostate cancer

Volume: 26, Pages: 71 - 78
Published: Jan 1, 2021
Abstract
Prostate radiotherapy relies on the delivery of high doses that can be obstructed when a small bowel loop descends in the pelvis. We present a laparoscopic minimally invasive prosthetic-free technique closing the Douglas' pouch with a peritoneal running suture to cordon off the bowel from the pelvis and hence allow optimal irradiation.Prostate cancer patients referred for radiotherapy and whose planning-CT revealed a bowel loop trapped in the...
Paper Details
Title
Laparoscopic closure of the pouch of Douglas by a peritoneal running suture. A minimally invasive and prosthetic-free technique to prevent excessive dose delivery to the small bowel during pelvic irradiation for prostate cancer
Published Date