Effectiveness of Menghini-Type Needles for Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Masses

Published on Sep 1, 2021in Digestive Diseases and Sciences2.751
· DOI :10.1007/S10620-020-06628-1
Sho Mizukawa6
Estimated H-index: 6
(Okayama University),
Hironari Kato20
Estimated H-index: 20
(Okayama University)
+ 10 AuthorsHiroyuki Okada62
Estimated H-index: 62
(Okayama University)
Sources
Abstract
BACKGROUND Cutting needles are thought to be effective as biopsy needles. A few types of cutting needles are available for endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), and the Menghini-type needle is an end-type cutting needle. AIMS A prospective randomized controlled trial was conducted to compare the results of EUS-FNA using a Menghini-type needle (needle M) versus a conventional needle (needle S). METHODS The main eligibility criteria were as follows: patients with a pancreatic mass referred for EUS-FNA, ≥ 20 years old, and a performance status < 4. The primary outcome was the sample quality. The secondary outcomes were factors associated with the sample quality, diagnostic accuracy, and adverse events. RESULTS A total of 97 patients were enrolled in this study. The sample quality for total puncture with needle M (92.8%) was significantly higher than that with needle S (81.4%) (p = 0.0305). The tumor size (p = 0.033) and type of needle (p = 0.031) were significant factors associated with adequate tissue collection in univariate and multivariate analyses (odds ratio [OR] 2.71; 95% confidence interval [CI] 1.12-6.54; p = 0.027 for tumor size, and OR 2.93; 95% CI 1.23-8.21; p = 0.0153 for type of needle). The diagnostic accuracy of each needle was 88.7% (86/97) with needle M and 73.2% (71/97) with needle S. Adverse events occurred in 2 of the 97 patients (0.02%). CONCLUSION A Menghini-type needle was able to obtain core tissue for histology more effectively than a conventional aspiration needle. TRIAL REGISTRATION NUMBERS UMIN registration number of 000020668.
📖 Papers frequently viewed together
22 Citations
9 Citations
1 Citations
References25
Newest
Abstract Background and aims The aim of this study was to compare the performance of EUS-guided fine-needle biopsy using fork-tip (SharkCore, Medtronic, USA) or side-fenestrated (ProCore, Cook Medical, Limerick, Ireland) needles in patients with solid pancreatic lesions. Methods This is a randomized controlled study conducted in a single academic center, including patients who underwent sampling with the fork-tip or the side-fenestrated 22-gauge or 25-gauge needles. Three passes were performed, ...
20 CitationsSource
#1David KarsentiH-Index: 6
#2Laurent PalazzoH-Index: 45
Last. Bertrand NapoleonH-Index: 28
view all 7 authors...
: BACKGROUND : Endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) has been suggested for obtaining high quality tissue samples from pancreatic tumors. We performed a multicenter randomized crossover trial comparing EUS-FNB with a 20G Procore needle vs. a 22G Acquire needle. The aims were to compare the quantity of targeted tissue (pancreas) and diagnostic accuracy for the two needles. METHODS : 60 patients admitted for EUS-FNB in three endoscopy units were included. One pass was performed...
13 CitationsSource
#1Milena Di Leo (Humanitas University)H-Index: 17
Last. Silvia CarraraH-Index: 20
view all 17 authors...
Abstract Background and aim Endoscopic ultrasound-guided sampling (EUS sampling) is a safe and effective technique. The study aim was to evaluate the presence of a histological core from pancreatic lesions using a new 25G fork-tip needle. Methods Observational multicenter prospective and analytical study, including consecutive patients with solid pancreatic masses referred for EUS-guided sampling. At each needle pass, the endoscopist performed macroscopic on-site evaluation (MOSE). The primary o...
18 CitationsSource
BackgroundInnovative approaches to improve diagnostic yield of endoscopic ultrasound-guided tissue acquisition (EUS-TA) have focused on needle design with development of fine-needle biopsy (FNB) needles with microcore-acquisition technology. Recently, a 20-gauge (20G) antegrade-cutting-side-bevelled biopsy needle (ProCore®) was developed for EUS-TA, but data about its diagnostic performance and histological capability are scant.ObjectivesWe assessed the diagnostic performance and histologic retr...
26 CitationsSource
#1Shuntaro Mukai (TMU: Tokyo Medical University)H-Index: 23
#2Takao Itoi (TMU: Tokyo Medical University)H-Index: 76
Last. Yuichi Nagakawa (TMU: Tokyo Medical University)H-Index: 23
view all 14 authors...
Background and Objectives: Recently, a 22G Franseen needle for EUS-guided fine-needle biopsy (EUS-FNB) with three novel symmetric heels has been developed to adequately obtain a core tissue. Methods: All 38 consecutive patients with pancreatic masses who underwent EUS-FNB using a Franseen needle were investigated retrospectively to assess the efficacy and safety of EUS-FNB using the Franseen needle. Then, the EUS-FNB outcomes and histological assessments of the tissue obtained by EUS-FNB using t...
43 CitationsSource
#1Brent K. LarsonH-Index: 7
#2Richard TuliH-Index: 28
Last. Andrew Eugene HendifarH-Index: 28
view all 6 authors...
OBJECTIVES: Endoscopic ultrasound-guided fine-needle biopsy and aspiration (EUS FNB/A) are the standard diagnostic tests for pancreatic malignancies. Oncologists increasingly use tumor genomic analysis for management. Adequacy of FNB/A tissue for next-generation sequencing (NGS) has not been evaluated. This study examined FNB/A and other biopsy types for features that might predict adequacy for NGS. METHODS: Seventy-six pancreatic exocrine malignancy biopsies submitted for NGS were assessed for ...
20 CitationsSource
#1Stefano Francesco Crinò (University of Verona)H-Index: 14
#2Maria Cristina Conti Bellocchi (University of Verona)H-Index: 5
Last. Armando Gabbrielli (University of Verona)H-Index: 26
view all 9 authors...
Abstract Background Early detection of small solid pancreatic lesions is increasingly common. To date, few and contradictory data have been published about the relationship between lesion size and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) diagnostic yield. The aim of this study was to assess the relation between the size of solid pancreatic lesions and the diagnostic yield of EUS-FNA using a 25-gauge needle in a center without available rapid on-site evaluation. Methods In th...
19 CitationsSource
#1Michael Larsen (OUH: Odense University Hospital)H-Index: 62
#2Claus Wilki Fristrup (OUH: Odense University Hospital)H-Index: 13
Last. Michael Bau Mortensen (OUH: Odense University Hospital)H-Index: 20
view all 4 authors...
Background and study aim Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions. The aim of this study was to evaluate the diagnostic accuracy. Patients and methods Single-center prospective study of 41 consecutive patients referred for EUS-FNB from October 2015 to April 2016 at ou...
18 CitationsSource
#1Sachin Wani (Anschutz Medical Campus)H-Index: 68
#2V. Raman Muthusamy (UCLA: University of California, Los Angeles)H-Index: 46
Last. Janak N. Shah (Ochsner Medical Center)H-Index: 34
view all 8 authors...
31 CitationsSource
#1Bin Cheng (HUST: Huazhong University of Science and Technology)H-Index: 1
#2Yueming Zhang (Peking Union Medical College)H-Index: 8
Last. Guiqi Wang (Peking Union Medical College)H-Index: 17
view all 13 authors...
Background & Aims Endoscopic ultrasound (EUS)-guided fine needles with side fenestrations are used to collect aspirates for cytology analysis and biopsy samples for histologic analysis. We conducted a large, multicenter study to compare the accuracy of diagnosis via specimens collected with fine-needle biopsy (FNB) versus fine-needle aspiration (FNA) for patients with pancreatic and nonpancreatic masses. Methods We performed a prospective single-blind study at 5 tertiary care centers in China. T...
67 CitationsSource
Cited By2
Newest
#1Yousuke Nakai (UTokyo: University of Tokyo)H-Index: 51
#2Tsuyoshi Hamada (UTokyo: University of Tokyo)H-Index: 38
Last. Kazuhiko Koike (UTokyo: University of Tokyo)H-Index: 91
view all 11 authors...
Source
#1Koichiro TsutsumiH-Index: 15
#2Toru UekiH-Index: 9
Last. Hiroyuki Okada (Okayama University)H-Index: 62
view all 9 authors...
BACKGROUND The histological diagnosis of autoimmune pancreatitis (AIP) by an endoscopic ultrasound (EUS)-guided approach is still challenging. METHODS We investigated the utility of the 21-gauge Menghini-type biopsy needle with the rolling method for the histological diagnosis of AIP, in comparison with conventional 22-gauge needles. Among total 28 patients, rate of definitive histological diagnosis, acquired sample area of tissue, rate of histopathological diagnosis of AIP, and adverse events w...
2 CitationsSource