Evaluation of reboiler temperature retention time on MEG degradation products at varying MEG concentrations

Volume: 196, Pages: 107735 - 107735
Published: Jan 1, 2021
Abstract
Mono ethylene glycol (MEG) has been used as a thermodynamic hydrate inhibitor in the gas industry. Due to its high usage, recoverability and environmental impact, MEG is regenerated instead of releasing to the environment. During the regeneration (distillation) process, MEG is exposed to higher temperatures in the reboiler to remove surplus water. When exposed to high temperatures, MEG thermal degradation process can occur due to dissociation to...
Paper Details
Title
Evaluation of reboiler temperature retention time on MEG degradation products at varying MEG concentrations
Published Date
Jan 1, 2021
Volume
196
Pages
107735 - 107735
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.