The corrosion-fatigue measurement test of the Zn-Al alloy coated steel wire
Abstract
In this paper, the S-N curve of Zn-Al alloy coated steel wire was obtained by setting 30 groups with different corrosion-fatigue tests. The results show that the corrosion-fatigue resistance of Zn-Al alloy coated steel wire is preferable to high-strength steel wire. The crack initiation time of Zn-Al alloy coated steel wire is longer than high-strength steel wire, and the propagation speed is far lower than high-strength steel wire. Finally, a...
Paper Details
Title
The corrosion-fatigue measurement test of the Zn-Al alloy coated steel wire
Published Date
Oct 1, 2020
Journal
Volume
27
Pages
1195 - 1201