The corrosion-fatigue measurement test of the Zn-Al alloy coated steel wire

Volume: 27, Pages: 1195 - 1201
Published: Oct 1, 2020
Abstract
In this paper, the S-N curve of Zn-Al alloy coated steel wire was obtained by setting 30 groups with different corrosion-fatigue tests. The results show that the corrosion-fatigue resistance of Zn-Al alloy coated steel wire is preferable to high-strength steel wire. The crack initiation time of Zn-Al alloy coated steel wire is longer than high-strength steel wire, and the propagation speed is far lower than high-strength steel wire. Finally, a...
Paper Details
Title
The corrosion-fatigue measurement test of the Zn-Al alloy coated steel wire
Published Date
Oct 1, 2020
Journal
Volume
27
Pages
1195 - 1201
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.