ZnSe quantum dot based ion imprinting technology for fluorescence detecting cadmium and lead ions on a three-dimensional rotary paper-based microfluidic chip

Published on Feb 15, 2020in Sensors and Actuators B-chemical7.46
· DOI :10.1016/J.SNB.2019.127462
Junrui Zhou2
Estimated H-index: 2
(Yantai University),
Bowei Li24
Estimated H-index: 24
(CAS: Chinese Academy of Sciences)
+ 4 AuthorsLingxin Chen101
Estimated H-index: 101
(CAS: Chinese Academy of Sciences)
Sources
Abstract
Abstract In this study, a newly fluorescent ZnSe quantum dots (QDs) with ion imprinting technology was firstly realized on the three-dimensional (3D) rotary paper–based microfluidic chip platform which can be used to realize specific and multiplexed detection of Cadmium ions (Cd2+) and Lead ions (Pb2+). Compared to CdTe quantum dots, ZnSe quantum dots are less toxic and more environmental friendly. In addition, this design improved the portability of the device by transferred the liquid phase of ZnSe QDs@ion imprinted polymers to solid glass fiber paper. Moreover, the 3D rotary microfluidic chip (μPADs) showed great advantages including low cost, simple and fast facile operation, multiplexed detection, and showed good sensitivity and selectivity. Under optimal experiment conditions, our proposed method was enabled to realize specific and multi-channel determination of Cd2+ and Pb2+ ions. The developed sensor of Cd2+ μPADs provided a linear response from 1 to 70 μg/L with a lower detection limit of 0.245 μg/L, and Pb2+ μPADs provided a linear response from 1 to 60 μg/L with a lower detection limit of 0.335 μg/L, respectively. Excitingly, this newly designed 3D rotary μPADs exhibited quantitative information conveniently, which showed the promising application prospects to rapid testing target metal ions in environmental in the future.
Download
📖 Papers frequently viewed together
References50
Newest
#1Ji Qi (CAS: Chinese Academy of Sciences)H-Index: 10
#2Bowei Li (CAS: Chinese Academy of Sciences)H-Index: 24
Last. Lingxin Chen (CAS: Chinese Academy of Sciences)H-Index: 101
view all 7 authors...
Abstract In this work, we provided a novel strategy of antibody-free biomarker analysis by in-situ synthesized molecularly imprinted polymers (MIPs) on movable valve microfluidic paper-based electrochemical device (Bio-MIP-ePADs) for clinical detection of biomarkers. The newly movable valves on the device enable continuous and convenient delivery of fluid, which guarantee the performance for fabricating MIPs structure during long time electropolymerization. Moreover, this strategy can directly d...
Source
#1Jiawang Ding (CAS: Chinese Academy of Sciences)H-Index: 20
#2Thomas Cherubini (University of Geneva)H-Index: 9
Last. Eric Bakker (CAS: Chinese Academy of Sciences)H-Index: 76
view all 4 authors...
Abstract We report here on paper-supported thin sample layer voltammetry for the determination of ions. To achieve this goal, a simple setup for the coupling of a commercially available electrode to a silver rod electrode was designed and evaluated for paper-supported thin-layer voltammetry. Linear scan ion transfer voltammetry was explored here for ion-selective membranes doped with an ionophore. The ion-transfer processes and electrochemical behaviors of the system are here evaluated and confi...
Source
#1Keisuke Tenda (Keio: Keio University)H-Index: 3
#2Benice van Gerven (TU/e: Eindhoven University of Technology)H-Index: 2
Last. Daniel Citterio (Keio: Keio University)H-Index: 39
view all 6 authors...
This work reports on fully integrated “sample-in-signal-out” microfluidic paper-based analytical devices (μPADs) relying on bioluminescence resonance energy transfer (BRET) switches for analyte recognition and colorimetric signal generation. The devices use BRET-based antibody sensing proteins integrated into vertically assembled layers of functionalized paper, and their design enables sample volume-independent and fully reagent-free operation, including on-device blood plasma separation. User o...
Source
#1Ji Qi (SHU: Shanghai University)H-Index: 10
#2Bowei Li (CAS: Chinese Academy of Sciences)H-Index: 24
Last. Lingxin Chen (CAS: Chinese Academy of Sciences)H-Index: 101
view all 6 authors...
In this study, we first present rotational paper-based microfluidic chips (RPADs) combined with a molecular-imprinting (MIP) technique to detect phenolic pollutants. The proposed rotational paper-based microfluidic chips could implement qualitative and quantitative analysis of two different phenolic contaminants, 4-nitrophenol (4-NP) and 2,4,6-trinitrophenol (TNP), simultaneously. Qualitative and quantitative analysis could be implemented simultaneously through fluorescence-intensity changes dep...
Source
#1Jinglong HanH-Index: 4
#2Anjin Qi (CAS: Chinese Academy of Sciences)H-Index: 3
Last. Lingxin Chen (CAS: Chinese Academy of Sciences)H-Index: 101
view all 6 authors...
A novel strategy for fabricating the paper-based valves on microfluidic paper-based analytical devices (μPADs) was described to control fluid in a user-friendly way. Initial prototypes of 3D μPADs manipulate the spatial distribution of fluid within the device. The movable paper channel in a different layer could be achieved using the channel’s connection or disconnection to realize the valve function using plastic comb binding spines (PCBS). The entire valve manipulation process was similar to a...
Source
#1Saravanan Rengaraj (University of Bath)H-Index: 8
#2Álvaro Cruz-Izquierdo (University of Bath)H-Index: 7
Last. Mirella Di Lorenzo (University of Bath)H-Index: 21
view all 4 authors...
Abstract According to the World Health Organisation, worldwide waterborne diseases are responsible for nearly two million human deaths annually. Rapid and at-site screen of pathogenic microorganisms in drinking water can help to markedly reduce this number. Here we report an innovative, simple and low-cost, paper-based probe for detection of bacteria in water, fabricated by screen printing carbon electrodes onto hydrophobic paper. Electrochemical characterization of the printed electrodes confir...
Source
#1Kentaro Yamada (CSU: Colorado State University)H-Index: 1
#2Daniel Citterio (Keio: Keio University)H-Index: 39
Last. Charles S. Henry (CSU: Colorado State University)H-Index: 65
view all 3 authors...
An improved paper-based analytical device (PAD) using color screening to enhance device performance is described. Current detection methods for PADs relying on the distance-based signalling motif can be slow due to the assay time being limited by capillary flow rates that wick fluid through the detection zone. For traditional distance-based detection motifs, analysis can take up to 45 min for a channel length of 5 cm. By using a color screening method, quantification with a distance-based PAD ca...
Source
#1Lijun Zhang (SNNU: Shaanxi Normal University)H-Index: 2
#2Xinyan Huang (SNNU: Shaanxi Normal University)H-Index: 5
Last. Liping Ding (SNNU: Shaanxi Normal University)H-Index: 29
view all 5 authors...
Enormous effort has been put to the detection and recognition of various heavy metal ions due to their involvement in serious environmental pollution and many major diseases. The present work has developed a single fluorescent sensor ensemble that can distinguish and identify a variety of heavy metal ions. A pyrene-based fluorophore (PB) containing a metal ion receptor group was specially designed and synthesized. Anionic surfactant sodium dodecyl sulfate (SDS) assemblies can effectively adjust ...
Source
#1Ji Qi (Yantai University)H-Index: 10
#2Bowei Li (CAS: Chinese Academy of Sciences)H-Index: 24
Last. Lingxin Chen (Yantai University)H-Index: 101
view all 7 authors...
In this study, a novel three-dimensional (3D) origami ion imprinted polymers microfluidic paper-based chip device for specific, sensitive and multiplexed detection of Cu2+ and Hg2+ ions has been proposed. In this device, the surface of the paper was activated by grafting with CdTe QDs through amino processing and formation of Cu2+ or Hg2+ IIPs and CdTe QDs complex that led to fluorescence quenching of QDs because the photo luminescent energy of QDs could be delivered to the complex. This method ...
Source
#1Xixi Xu (Jiangsu University)H-Index: 3
#2Dong Liu (Jiangsu University)H-Index: 15
Last. Tianyan You (Jiangsu University)H-Index: 18
view all 6 authors...
Abstract A novel CdTe quantum dots - single walled carbon nanohorns (CdTe-SWCNHs) nanocomposite was synthesized via a one-pot method for photoelectrochemical (PEC) aptasensing detection of streptomycin (STR). The CdTe-SWCNHs nanocomposite shows 3.2-times amplified PEC activity in comparison with CdTe quantum dots (QDs). By using aptamers as recognition element and CdTe-SWCNHs as photoactive species, a PEC aptasensor was fabricated for the high sensitive and selective detection of STR. Under the ...
Source
Cited By43
Newest
#1Mohamed E. Mahmoud (Alexandria University)H-Index: 55
#2Magda E. Abouelanwar (Alexandria University)H-Index: 5
Last. Mohamed Abdel Salam (KAU: King Abdulaziz University)H-Index: 30
view all 4 authors...
Abstract null null Recent industrial development and research progress in nanotechnology have led to the release of a number of nanomaterials with particle sizes (1-10 nm) which are categorized as quantum dots (QDs) in aquatic system. Disposal away of such QDs will cause potential pollution to the environment. Therefore, removal of disposed QDs from wastewater represents a challenging research subject for scientists and engineers. Hence, the objective of this study is devoted to assess the proce...
Source
#8Ping Liu (CAS: Chinese Academy of Sciences)H-Index: 20
Abstract null null We firstly constructed a kind of self-powered rotating paper-based microfluidic chip and used it to detect thrombin. The integrated movable valve has the ability to control the fluid user-friendly on microfluidic paper-based analytical devices (µPADs), and this advantage let it convenient to implement the complex multistep operations. In addition, this technique is compatible and versatile to the self-powered µPADs at differing levels of complexity. To obtain the supercapacito...
Source
#3Emanuel Carrilho (USP: University of São Paulo)H-Index: 46
Source
#1Ruiyu Ding (NTU: Nanyang Technological University)H-Index: 8
#2Yi Heng Cheong (NTU: Nanyang Technological University)H-Index: 4
Last. Grzegorz Lisak (NTU: Nanyang Technological University)H-Index: 27
view all 4 authors...
Abstract null null To address analysis of heavy metals in samples containing low volumes and/or high solid-to-liquid contents, microfluidic paper-based solution sampling coupled with Pb2+-ISEs was investigated. The acidification of paper substrates prior to their use was found effective at eliminating the otherwise observed super-Nernstian response of Pb2+-ISEs. Acidified paper substrates (at different pH) were evaluated and through 3D approximate (concentration-EMF-pH) analyses of the Pb2+-ISEs...
Source
#1Xiaoxiao Qin (SNNU: Shaanxi Normal University)H-Index: 3
Abstract null null Microfluidic paper-based chips (μPCs) are micro-laboratory analysis systems that use paper instead of traditional microfluidic substrate materials and miniaturize biochemical reactions. Based on traditional 2D μPCs, the novel μPCs are innovative 3D structure chips that are realized by fluid channel construction, channel microvalve, folding and other fluid control methods. In recent years, μPCs have developed rapidly in terms of design and integration and have been widely used ...
Source
#1Xinyi Wang (SPbU: Saint Petersburg State University)
#2Liubing Kong (ZJU: Zhejiang University)H-Index: 4
Last. Ping Wang (ZJU: Zhejiang University)H-Index: 36
view all 10 authors...
Abstract null null Heavy metal pollution has severe threats to the ecological environment and human health. Thus, it is urgent to achieve the rapid, selective, sensitive and portable detection of heavy metal ions. To overcome the defects of traditional methods such as time-consuming, low sensitivity, high cost and complicated operation, QDs (Quantum dots)-based nanomaterials have been used in sensors to significantly improve the sensing performance. Due to their excellent physicochemical propert...
Source
#1Chin Chung Tseng (NCKU: National Cheng Kung University)H-Index: 22
#2Chia Te Kung (NCKU: National Cheng Kung University)H-Index: 4
Last. Lung-Ming FuH-Index: 47
view all 7 authors...
Abstract Microfluidic paper-based analysis devices (μPADs) have undergone tremendous development in recent years and now provide a feasible low-cost alternative to traditional laboratory tests for the diagnosis of many common diseases and disorders. As such, they are of great interest and importance in developing regions of the world with a lack of medical resources and associated infrastructures. This review examines the advances made in microfluidic paper-based diagnostic technology in the pas...
Source
#1Tomas Rypar (Mendel University)H-Index: 1
#2Vojtech Adam (Mendel University)H-Index: 70
Last. Mirek Macka (Mendel University)H-Index: 19
view all 4 authors...
Abstract Microfluidic paper-based analytical devices (μPADs) offer the advantages of simplicity, extremely low costs, robustness, and miniaturisation, synergistically supporting portability and point-of-care (POC) analysis. When μPADs are combined with distance-based detection in DμPADs, they uniquely enable a quantitative analytical platform that is truly instrumentation-free (naked-eye readout), or at least, does not require any specialised scientific instrumentation (only mobile phone camera)...
Source
#1Silindokuhle Jakavula (UJ: University of Johannesburg)H-Index: 2
#2N. Raphael Biata (UJ: University of Johannesburg)H-Index: 6
Last. Philiswa N. Nomngongo (UJ: University of Johannesburg)H-Index: 22
view all 5 authors...
Abstract Simultaneous extraction and preconcentration of several potentially toxic metal ions have received great attention because of their toxicological effects on aquatic life and human beings. Multi-ion imprinted polymers (MIIP) have proved to be promising adsorbents with excellent specific recognition performance than single-ion imprinted polymer. Therefore, in this study, the MIIP strategy was employed for simultaneous extraction and enrichment of Sb(III), Cd(II), Pb(II) and Te(IV) ions fr...
Source
#5Lianxin Liu (USTC: University of Science and Technology of China)H-Index: 45
The spread of Coronavirus disease 2019 (COVID-19) is caused by severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2), resulting in a global pandemic with around four million deaths. Although there are a variety of nucleic acid-based tests for detecting SARS-CoV-2, these methods have a relatively high cost and require expensive supporting equipment. To overcome these limitations and improve the efficiency of SARS-CoV-2 diagnosis, we developed a microfluidic platform that collected serum by...
Source
This website uses cookies.
We use cookies to improve your online experience. By continuing to use our website we assume you agree to the placement of these cookies.
To learn more, you can find in our Privacy Policy.