Possible artifacts in dynamic CEST MRI due to motion and field alterations

Published on Jan 1, 2019in Journal of Magnetic Resonance2.624
· DOI :10.1016/J.JMR.2018.11.002
Moritz Zaiss28
Estimated H-index: 28
(MPG: Max Planck Society),
Kai Herz8
Estimated H-index: 8
(MPG: Max Planck Society)
+ 6 AuthorsKlaus Scheffler76
Estimated H-index: 76
(MPG: Max Planck Society)
Sources
Abstract
Abstract Purpose Dynamic CEST studies such as dynamic glucose enhanced imaging, have gained a lot of attention recently. The expected CEST effects after injection are rather small in tissue especially at clinical field strengths (0.5–2%). Small movements during the dynamic CEST measurement together with a subtraction-based evaluation can lead to pseudo CEST effects of the same order of magnitude. These artifacts are studied herein. Methods A brain tumor patient 3D-CEST baseline scan without glucose injection performed at 3 T is used to generate a virtual dynamic measurement introducing different kinds of simulated motion and B0 shifts. Results Minor motion (0.6 mm translations) and B0 artifacts (7 Hz shift) can lead to pseudo effects in the order of 1% in dynamic CEST imaging. Especially around tissue interfaces such as CSF borders or tumor affected areas, the pseudo effect patterns are non-intuitive and can be mistaken as dynamic agent uptake. Conclusion Correction or mitigation for small motions is crucial for dynamic CEST imaging, especially in subjects with lesions. Concomitant B0 alterations can as well induce pseudo CEST effects at 3 T.
📖 Papers frequently viewed together
326 Citations
232 Citations
62 Citations
References19
Newest
#1Anagha Deshmane (MPG: Max Planck Society)H-Index: 12
#2Moritz Zaiss (MPG: Max Planck Society)H-Index: 28
Last. Klaus Scheffler (MPG: Max Planck Society)H-Index: 76
view all 9 authors...
PURPOSE: For clinical implementation, a chemical exchange saturation transfer (CEST) imaging sequence must be fast, with high signal-to-noise ratio (SNR), 3D coverage, and produce robust contrast. However, spectrally selective CEST contrast requires dense sampling of the Z-spectrum, which increases scan duration. This article proposes a compromise: using a 3D snapshot gradient echo (GRE) readout with optimized CEST presaturation, sampling, and postprocessing, highly resolved Z-spectroscopy at 3T...
21 CitationsSource
#1Johannes Windschuh (NYU: New York University)H-Index: 15
#2Moritz Zaiss (MPG: Max Planck Society)H-Index: 28
Last. Ravinder R. Regatte (NYU: New York University)H-Index: 41
view all 6 authors...
PURPOSE: To investigate the effect of a frequency drift of the static magnetic field on 3D CEST MRI based on glycosaminoglycans (GAGs) of articular cartilage at 7 T and to introduce a retrospective correction method that uses the phase images of the gradient-echo readout. METHODS: Repeated gagCEST and B0 measurements were performed in a glucose model solution and in vivo in the knee joint of 3 healthy volunteers at 7 T. Phase images of the modified 3D rectangular spiral centric-reordered gradien...
23 CitationsSource
#1Kai Herz (University of Tübingen)H-Index: 8
#2C Gandhi (MPG: Max Planck Society)H-Index: 2
Last. Moritz Zaiss (MPG: Max Planck Society)H-Index: 28
view all 6 authors...
PURPOSE: The CEST experiment, with its correlation to rare proton species that are in exchange with the water pool, is very similar to the off-resonant water spin-lock (SL) experiment. In particular, low-power SL Z-spectrum acquisition allows insight into T1ρ and exchange effects with decreased direct water saturation. Because the available SL methods either require high B1 power or are instable in the presence of strong B1 and B0 inhomogeneity present at ultra-high fields, the goal of this stud...
9 CitationsSource
#1Patrick Schuenke (DKFZ: German Cancer Research Center)H-Index: 9
#2C Koehler (DKFZ: German Cancer Research Center)H-Index: 3
Last. Moritz Zaiss (DKFZ: German Cancer Research Center)H-Index: 28
view all 13 authors...
Purpose Chemical exchange sensitive spin-lock and related techniques allow to observe the uptake of administered D-glucose in vivo. The exchange-weighting increases with the magnetic field strength, but inhomogeneities in the radiofrequency (RF) field at ultrahigh field whole-body scanners lead to artifacts in conventional spin-lock experiments. Thus, our aim was the development of an adiabatically prepared T1ρ-based imaging sequence applicable to studies of glucose metabolism in tumor patients ...
48 CitationsSource
#1Daniel Paech (DKFZ: German Cancer Research Center)H-Index: 20
#2Patrick Schuenke (DKFZ: German Cancer Research Center)H-Index: 9
Last. Alexander Radbruch (DKFZ: German Cancer Research Center)H-Index: 41
view all 16 authors...
T1ρ-weighted dynamic glucose-enhanced contrast can be obtained with sufficient sensitivity and temporal resolution to quantitatively image brain glucose physiology in healthy humans and pathophysiologically increased glucose uptake of tumors in patients with glioblastoma at 7.0 T.
40 CitationsSource
#1Patrick Schuenke (DKFZ: German Cancer Research Center)H-Index: 9
#2Daniel Paech (DKFZ: German Cancer Research Center)H-Index: 20
Last. Moritz Zaiss (MPG: Max Planck Society)H-Index: 28
view all 9 authors...
Common medical imaging techniques usually employ contrast agents that are chemically labeled, e.g. with radioisotopes in the case of PET, iodine in the case of CT or paramagnetic metals in the case of MRI to visualize the heterogeneity of the tumor microenvironment. Recently, it was shown that natural unlabeled D-glucose can be used as a nontoxic biodegradable contrast agent in Chemical Exchange sensitive Spin-Lock (CESL) magnetic resonance imaging (MRI) to detect the glucose uptake and potentia...
33 CitationsSource
#1Patrick Schuenke (DKFZ: German Cancer Research Center)H-Index: 9
#2Johannes Windschuh (DKFZ: German Cancer Research Center)H-Index: 15
Last. Moritz Zaiss (DKFZ: German Cancer Research Center)H-Index: 28
view all 6 authors...
Purpose Together with the development of MRI contrasts that are inherently small in their magnitude, increased magnetic field accuracy is also required. Hence, mapping of the static magnetic field (B0) and the excitation field (B1) is not only important to feedback shim algorithms, but also for postprocess contrast-correction procedures. Methods A novel field-inhomogeneity mapping method is presented that allows simultaneous mapping of the water shift and B1 (WASABI) using an off-resonant rectan...
56 CitationsSource
#1Jihong WangH-Index: 15
#2Joseph Weygand (University of Texas MD Anderson Cancer Center)H-Index: 5
Last. Jinyuan Zhou (Johns Hopkins University)H-Index: 1
view all 9 authors...
Magnetic Resonance Imaging of Glucose Uptake and Metabolism in Patients with Head and Neck Cancer
42 CitationsSource
#1Xiang Xu (JHUSOM: Johns Hopkins University School of Medicine)H-Index: 15
#2Nirbhay N. Yadav (JHUSOM: Johns Hopkins University School of Medicine)H-Index: 20
Last. Peter C.M. van ZijlH-Index: 109
view all 16 authors...
Recent animal studies have shown that D-glucose is a potential biodegradable MRI contrast agent for imaging glucose uptake in tumors. Here, we show the first translation of that use of D-glucose to human studies. Chemical exchange saturation transfer (CEST) MRI at a single frequency offset optimized for detection of hydroxyl protons in D-glucose (glucoCEST) was used to image dynamic signal changes in the human brain at 7T during and after infusion of D-glucose. Dynamic glucose-enhanced (DGE) ima...
102 CitationsSource
#1Xiang Xu (ICSCI: Kennedy Krieger Institute)H-Index: 15
#2Kannie W.Y. Chan (ICSCI: Kennedy Krieger Institute)H-Index: 23
Last. Peter C.M. van Zijl (ICSCI: Kennedy Krieger Institute)H-Index: 109
view all 11 authors...
Recently, natural d-glucose was suggested as a potential biodegradable contrast agent. The feasibility of using d-glucose for dynamic perfusion imaging was explored to detect malignant brain tumors based on blood brain barrier breakdown.
62 CitationsSource
Cited By22
Newest
#1Lin Chen (JHUSOM: Johns Hopkins University School of Medicine)H-Index: 13
#1Lin X. Chen (ICSCI: Kennedy Krieger Institute)H-Index: 71
Last. Jiadi Xu (JHUSOM: Johns Hopkins University School of Medicine)H-Index: 34
view all 13 authors...
In this study, we applied on-resonance variable delay multiple pulse (onVDMP) MRI to study D-glucose uptake in a mouse model of Alzheimer's disease (AD) tauopathy and demonstrated its feasibility in discriminating AD mice from wild-type mice. The D-glucose uptake in the cortex of AD mice (1.70 ± 1.33%) was significantly reduced compared to that of wild-type mice (5.42 ± 0.70%, p = 0.0051). Also, a slower D-glucose uptake rate was found in the cerebrospinal fluid (CSF) of AD mice (0.08 ± 0.01 min...
2 CitationsSource
#1Soo Hyun Shin (University of California, Berkeley)H-Index: 1
#2Michael F. Wendland (University of California, Berkeley)H-Index: 66
Last. Moriel Vandsburger (University of California, Berkeley)H-Index: 5
view all 3 authors...
Purpose We demonstrate a method of delayed urea differential enhancement CEST for probing urea recycling action of the kidney using expanded multi-pool Lorentzian fitting and apparent exchange-dependent relaxation compensation. Methods T1 correction of urea CEST contrast by apparent exchange-dependent relaxation was tested in phantoms. Nine mice were scanned at 7 Tesla following intraperitoneal injection of 2M 150 μL urea, and later saline. T1 maps and Z-spectra were acquired before and 20 and 4...
Source
#1Jicheng Wang (University of Pittsburgh)H-Index: 19
#2Mitsuhiro Fukuda (University of Pittsburgh)H-Index: 15
Last. Tao Jin (University of Pittsburgh)H-Index: 35
view all 5 authors...
Purpose Glucose and its analogs can be detected by CEST and chemical exchange spin-lock (CESL) MRI techniques, but sensitivity is still a bottleneck for human applications. Here, CESL and CEST sensitivity and the effect of injection on baseline physiology were evaluated for a glucose analog, xylose. Methods The CEST and CESL sensitivity were evaluated at 9.4 T in phantoms and by in vivo rat experiments with 0.5 and 1 g/kg xylose injections. Arterial blood glucose level was sampled before and aft...
1 CitationsSource
PURPOSE To explore the impact of temporal motion-induced coil sensitivity changes on CEST-MRI at 7T and its correction using interleaved volumetric EPI navigators, which are applied for real-time motion correction. METHODS Five healthy volunteers were scanned via CEST. A 4-fold correction pipeline allowed the mitigation of (1) motion, (2) motion-induced coil sensitivity variations, ΔB1- , (3) motion-induced static magnetic field inhomogeneities, ΔB0 , and (4) spatially varying transmit RF field ...
Source
#1A Liebert (FAU: University of Erlangen-Nuremberg)H-Index: 1
#2Katharina Tkotz (FAU: University of Erlangen-Nuremberg)H-Index: 1
Last. Armin M. Nagel (FAU: University of Erlangen-Nuremberg)H-Index: 31
view all 13 authors...
PURPOSE To enable whole-brain quantitative CEST MRI at ultra-high magnetic field strengths (B0 ≥ 7T) within short acquisition times. METHODS Multiple interleaved mode saturation (MIMOSA) was combined with fast online-customized (FOCUS) parallel transmission (pTx) excitation pulses and B1+ correction to achieve homogenous whole-brain coverage. Examinations of 13 volunteers were performed on a 7T MRI system with 3 different types of pulse sequences: (1) saturation in circular polarized (CP) mode a...
Source
Conventional medical imaging techniques use contrast agents that are chemically labeled, for example, iodine in the case of computed tomography, radioisotopes in the case of PET, or gadolinium in the case of MR imaging to create or enhance signal contrast and to visualize tissue compartments and features. Dynamic glucose-enhanced MR imaging represents a novel technique that uses natural, unlabeled d-glucose as a nontoxic biodegradable contrast agent in chemical exchange-sensitive MR imaging appr...
2 CitationsSource
#1Grzegorz Kwiatkowski (UZH: University of Zurich)H-Index: 8
#2Sebastian Kozerke (UZH: University of Zurich)H-Index: 61
PURPOSE Chemical exchange saturation transfer (CEST) is an MR contrast modality offering an enhanced sensitivity for the detection of dilute metabolites with exchangeable protons. Quantitative analysis requires the acquisition of a number of images (usually between 20 and 50 RF offsets) per Z-spectrum, leading to long acquisition times of the order of 5-40 min in practice. In this work, we explore the possibility of employing sparsity in the Z-spectrum domain (irradiation offset dimension) to pr...
Source
#1Philip S. Boyd (DKFZ: German Cancer Research Center)H-Index: 3
#2Johannes Breitling (DKFZ: German Cancer Research Center)H-Index: 5
Last. Steffen Goerke (DKFZ: German Cancer Research Center)H-Index: 14
view all 12 authors...
PURPOSE: Dynamic glucose-enhanced (DGE)-MRI based on chemical exchange-sensitive MRI, that is, glucoCEST and gluco-chemical exchange-sensitive spin-lock (glucoCESL), is intrinsically prone to motion-induced artifacts because the final DGE contrast relies on the difference of images, which were acquired with a time gap of several mins. In this study, identification of different types of motion-induced artifacts led to the development of a 3D acquisition protocol for DGE examinations in the human ...
3 CitationsSource
#1F Glang (MPG: Max Planck Society)H-Index: 3
#2Anagha Deshmane (MPG: Max Planck Society)H-Index: 12
Last. Moritz Zaiss (MPG: Max Planck Society)H-Index: 28
view all 9 authors...
PURPOSE: Calculation of sophisticated MR contrasts often requires complex mathematical modeling. Data evaluation is computationally expensive, vulnerable to artifacts, and often sensitive to fit algorithm parameters. In this work, we investigate whether neural networks can provide not only fast model fitting results, but also a quality metric for the predicted values, so called uncertainty quantification, investigated here in the context of multi-pool Lorentzian fitting of CEST MRI spectra at 3T...
10 CitationsSource
#1Xiang Xu (JHUSOM: Johns Hopkins University School of Medicine)H-Index: 15
#2Akansha Ashvani Sehgal (JHUSOM: Johns Hopkins University School of Medicine)H-Index: 3
Last. Peter C.M. van Zijl (JHUSOM: Johns Hopkins University School of Medicine)H-Index: 109
view all 11 authors...
PURPOSE: Dynamic glucose enhanced (DGE) MRI has shown potential for imaging glucose delivery and blood-brain barrier permeability at fields of 7T and higher. Here, we evaluated issues involved with translating d-glucose weighted chemical exchange saturation transfer (glucoCEST) experiments to the clinical field strength of 3T.METHODS: Exchange rates of the different hydroxyl proton pools and the field-dependent T2 relaxivity of water in d-glucose solution were used to simulate the water saturati...
11 CitationsSource