Original paper

Effect of the dimple location and rotating number on the heat transfer and flow structure in a pin finned channel

Volume: 127, Pages: 111 - 129
Published: Dec 1, 2018
Abstract
In this study, the Realizable k-ε turbulent model combined with the wall enhanced function is used to evaluate the heat transfer and flow structure in a rotating pin finned channel with different dimple locations. The Re number is fixed at 7000. The Ro number is varied from 0 to 1.0. Three different dimple locations are introduced to investigate the effect of the dimple location on heat transfer and flow structure. The streamline, dissipative...
Paper Details
Title
Effect of the dimple location and rotating number on the heat transfer and flow structure in a pin finned channel
Published Date
Dec 1, 2018
Volume
127
Pages
111 - 129
Citation AnalysisPro