Long-term electrical performance of Attain Performa quadripolar left ventricular leads with all steroid-eluting electrodes: Results from a large worldwide clinical trial

Published on May 29, 2018in Pacing and Clinical Electrophysiology1.303
· DOI :10.1111/PACE.13389
Albert C. Lin16
Estimated H-index: 16
(NU: Northwestern University),
Mauro Biffi50
Estimated H-index: 50
(UNIBO: University of Bologna)
+ 8 AuthorsGeorge H. Crossley20
Estimated H-index: 20
(Vandy: Vanderbilt University)
Sources
Abstract
BACKGROUND: Steroid-eluting (SE) electrodes suppress local inflammation and lower pacing capture thresholds (PCT); however, their effectiveness on quadripolar left ventricular (LV) leads in the cardiac vein is not fully studied. We evaluated the effectiveness of SE on all four LV pacing electrodes in human subjects enrolled in the Medtronic Attain® Performa™ quadripolar LV lead study. METHODS: A total of 1,097 subjects were included in this evaluation. At each follow-up visit (1, 3, 6, and 12 months), LV PCT and pacing impedance were measured using either manual or automated testing methods. Summary statistics for PCT and impedance values were obtained for implant and each scheduled follow-up visit for all lead models. RESULTS: Average extended bipolar (LV electrode to right ventricular Coil) PCTs for the four LV SE pacing electrodes (LV1, LV2, LV3, and LV4) on the three shapes of the quadripolar LV leads were 1.06 ± 0.97 V, 1.38 ± 1.26 V, 1.51 ± 1.33 V, and 2.25 ± 1.63 V, respectively, at 0.5-ms pulse width. PCTs remained low and stable throughout the 12-month follow-up period. CONCLUSION: This clinical trial demonstrated that SE on all LV pacing electrodes is associated with low and stable PCTs for all quadripolar LV lead electrodes, resulting in multiple viable vectors for LV pacing. The large number of available vectors facilitates basal pacing, avoidance of PNS, and potentially prolongs generator longevity due to lower PCTs.
📖 Papers frequently viewed together
13 Citations
2 Citations
9 Citations
References17
Newest
#1W. Ben JohnsonH-Index: 7
Last. Subham GhoshH-Index: 12
view all 13 authors...
Background Electrical heterogeneity (EH) during cardiac resynchronization therapy may vary with different left ventricular (LV) pacing sites. Objective The purpose of this study was to evaluate the relationship between such changes and acute hemodynamic response (AHR). Methods Two EH metrics—standard deviation of activation times and mean left thorax activation times—were computed from isochronal maps based on 53-electrode body surface mapping during baseline AAI pacing and biventricular (BiV) p...
28 CitationsSource
Last. D O Martin Burke (U of C: University of Chicago)H-Index: 1
view all 11 authors...
Anatomically Designed Quadripolar LV LeadsIntroduction The safety and efficacy of a novel family of quadripolar left ventricular (LV) pacing leads designed to pace from nonapical regions of the LV with low pacing capture thresholds was studied in patients undergoing implantation of a cardiac resynchronization therapy defibrillator (CRT-D). Methods and Results Patients receiving a CRT-D were implanted with 1 of 3 ACUITY X4 leads (Spiral Long, Spiral Short, or Straight), designed to address corona...
12 CitationsSource
#1David O'DonnellH-Index: 13
#2Johannes SperzelH-Index: 29
Last. Gery Tomassoni (Baptist Health)H-Index: 15
view all 12 authors...
Aims The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). Methods and results A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors define...
9 CitationsSource
Introduction The use of steroid elution (SE) electrode in a cardiac pacing lead is known to suppress myocardial inflammation to lower pacing thresholds (PTs). SE has been widely utilized on the distal electrode of left ventricular cardiac vein (LVCV) leads used in cardiac resynchronization therapy (CRT). However, no paired comparison in effect of SE has been studied in proximal electrodes of quadripolar LVCV leads. Methods We evaluated electrical performance and tissue responses of quadripolar L...
5 CitationsSource
#1Wouter M. van Everdingen (UU: Utrecht University)H-Index: 8
#2Maarten J. Cramer (UU: Utrecht University)H-Index: 40
Last. Mathias Meine (UU: Utrecht University)H-Index: 19
view all 4 authors...
Abstract Despite the benefit of cardiac resynchronization therapy (CRT) in patients with heart failure and conduction delay, a considerable number of patients do not respond substantially. Left ventricular lead position is an important factor in response, restricted by the patient’s specific anatomy and local pathophysiology. Quadripolar leads could enhance response to CRT, offering 4 pacing locations along the distal end of the lead. Several quadripolar leads are available, all with different s...
16 CitationsSource
#1Daniel A. Steinhaus (BIDMC: Beth Israel Deaconess Medical Center)H-Index: 4
#2Jonathan W. Waks (BIDMC: Beth Israel Deaconess Medical Center)H-Index: 15
Last. Peter Zimetbaum (BIDMC: Beth Israel Deaconess Medical Center)H-Index: 59
view all 6 authors...
Device longevity in cardiac resynchronization therapy (CRT) is affected by the pacing capture threshold (PCT) and programmed pacing amplitude of the left ventricular (LV) pacing lead. The aims of this study were to evaluate the stability of LV pacing thresholds in a nationwide sample of CRT defibrillator recipients and to determine potential longevity improvements associated with a decrease in the LV safety margin while maintaining effective delivery of CRT. CRT defibrillator patients in the Med...
8 CitationsSource
#1Francois PhilipponH-Index: 2
#2Lili LiuH-Index: 1
Last. Franck MolinH-Index: 1
view all 12 authors...
Aims This multicenter acute clinical study was designed to verify novel three-dimensional (3D) quadripolar lead designs that can achieve ≤2.5 V average pacing capture threshold (PCT) not only at the apex, but also at the base of the left ventricle with phrenic nerve stimulation (PNS) avoidance for cardiac resynchronization. Methods During the implant procedure, up to two different left ventricular investigational leads were introduced and tested in the same target coronary vein based on the coro...
6 CitationsSource
#1George H. Crossley (Vandy: Vanderbilt University)H-Index: 20
#2Mauro BiffiH-Index: 50
Last. Derek V. Exner (U of C: University of Calgary)H-Index: 36
view all 12 authors...
Background The Medtronic Attain Performa quadripolar leads provide 16 pacing vectors with steroid on every electrode. This includes a short bipolar configuration between the middle 2 electrodes. Objective A prospective clinical study was conducted to investigate the safety and effectiveness of these new leads in 27 countries. Methods Cardiac resynchronization therapy with defibrillator candidates were enrolled (mean age 68 years; 71% men). All implanted subjects were followed at 1, 3, and 6 mont...
36 CitationsSource
#1Harry G. Mond (University of Melbourne)H-Index: 31
#2John R. Helland (St. Jude Medical)H-Index: 6
Last. Rick D. Mcvenes (Medtronic plc)H-Index: 12
view all 5 authors...
25 CitationsSource
#1Suneet MittalH-Index: 37
#2Richard E. ShawH-Index: 60
Last. Jonathan S. SteinbergH-Index: 65
view all 9 authors...
RESULTS In the pre-envelope era, an infection occurred in 25 (1.5%) of 1651 patients. After its availability, an envelope was used in 275 (22%) of 1240 patients; an infection occurred in 8 (0.6%) patients in this era (P ¼ .029 vs pre-envelope). In the overall cohort of 2891 patients, the infection rate was 1.2% and 3.5% in patients with an implantable cardioverter-defibrillator device and those with a cardiac resynchronization therapy defibrillator device, respectively (P ¼ .018); in these patie...
108 CitationsSource
Cited By4
Newest
Background. A neuroprosthesis (NP) is a medical device that compensates and restores functionality of neural dysfunctions affected by different pathologies and conditions. To this end, an implantable NP (INP) must monitor and electrically stimulate neuronal small structures in the peripheral and central nervous system. Therefore, one of the most important parts of INPs are the sensors and electrodes since their size, resolution, and material are key for their design and performance. Currently, m...
Source
#1Kevin P. Jackson (Duke University)H-Index: 12
#2Svein Faerestrand (Haukeland University Hospital)H-Index: 13
Last. George H. Crossley (Vandy: Vanderbilt University)H-Index: 20
view all 12 authors...
INTRODUCTION: The Medtronic Attain Stability Quad lead is a quadripolar left ventricular (LV) lead with an active fixation helix assembly designed to fixate the lead within the coronary sinus and pace nonapical regions of the LV. The primary objective of this study was to determine the safety and effectiveness of this novel active fixation quadripolar LV lead. METHODS: Patients with standard indications for cardiac resynchronization therapy (CRT) were enrolled. All patients were followed at 3 an...
5 CitationsSource
#1Haran BurriH-Index: 35
#2Max Olaf SchrageH-Index: 1
Last. Mauro BiffiH-Index: 50
view all 10 authors...
BACKGROUND: Various lead designs have been developed to accommodate different coronary sinus anatomies. Our objectives were to compare electrical parameters of straight and spiral left ventricular leads, to evaluate capture thresholds and impedances using different pacing vectors, and to study evolution of thresholds over time. METHODS: The RALLY-X4 study enrolled patients implanted with a lead from the Acuity X4 family (straight, spiral short, or spiral long). Electrical parameters (including c...
3 CitationsSource