Double Shear Testing of Cable Bolts with No Concrete Face Contacts

Volume: 191, Pages: 1169 - 1177
Published: Jan 1, 2017
Abstract
A new series of double shear tests were carried out using a newly modified double shear apparatus which prevented contacts between concrete block surfaces during shearing. 13 double shear tests were carried out using 21 mm diameter 19 (9 × 9 × 1) seal construction wire strand cable (also called Superstrand cable), Plain SUMO, Indented SUMO, Spiral MW9 and Plain MW10 cable bolts. These cables were tested subjected to different pretension loads....
Paper Details
Title
Double Shear Testing of Cable Bolts with No Concrete Face Contacts
Published Date
Jan 1, 2017
Volume
191
Pages
1169 - 1177
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.