Detection of increased vasa vasorum in artery walls: Improving CT number accuracy using image deconvolution.

Published on Feb 11, 2017in Proceedings of SPIE
· DOI :10.1117/12.2255676
Kishore Rajendran11
Estimated H-index: 11
(Mayo Clinic),
Shuai Leng53
Estimated H-index: 53
(Mayo Clinic)
+ 3 AuthorsCynthia H. McCollough76
Estimated H-index: 76
(Mayo Clinic)
Sources
Abstract
Changes in arterial wall perfusion are an indicator of early atherosclerosis. This is characterized by an increased spatial density of vasa vasorum (VV), the micro-vessels that supply oxygen and nutrients to the arterial wall. Detection of increased VV during contrast-enhanced computed tomography (CT) imaging is limited due to contamination from blooming effect from the contrast-enhanced lumen. We report the application of an image deconvolution technique using a measured system point-spread function, on CT data obtained from a photon-counting CT system to reduce blooming and to improve the CT number accuracy of arterial wall, which enhances detection of increased VV. A phantom study was performed to assess the accuracy of the deconvolution technique. A porcine model was created with enhanced VV in one carotid artery; the other carotid artery served as a control. CT images at an energy range of 25-120 keV were reconstructed. CT numbers were measured for multiple locations in the carotid walls and for multiple time points, pre and post contrast injection. The mean CT number in the carotid wall was compared between the left (increased VV) and right (control) carotid arteries. Prior to deconvolution, results showed similar mean CT numbers in the left and right carotid wall due to the contamination from blooming effect, limiting the detection of increased VV in the left carotid artery. After deconvolution, the mean CT number difference between the left and right carotid arteries was substantially increased at all the time points, enabling detection of the increased VV in the artery wall.
📖 Papers frequently viewed together
2 Citations
10 Citations
2012ICIP: International Conference on Image Processing
6 Authors (Michael Hirsch, ..., Michael Habeck)
References9
Newest
#1Steven M. Jorgensen (Mayo Clinic)H-Index: 15
#2Mark Korinek (Mayo Clinic)H-Index: 2
Last. Erik L. Ritman (Mayo Clinic)H-Index: 77
view all 8 authors...
Early atherosclerosis changes perfusion of the arterial wall due to localized proliferation of the vasa vasorum. When contrast agent passes through the artery, some enters the vasa vasorum and increases radiopacity of the arterial wall. Technical challenges to detecting changes in vasa vasorum density include the thin arterial wall, partial volume averaging at the arterial lumen/wall interface and calcification within the wall. We used a photon-counting spectral CT scanner to study carotid arter...
6 CitationsSource
#1Zhicong Yu (Mayo Clinic)H-Index: 11
#2Shuai LengH-Index: 53
Last. Cynthia H. McColloughH-Index: 76
view all 7 authors...
A research photon-counting computed tomography (CT) system that consists of an energy-integrating detector (EID) and a photon-counting detector (PCD) was installed in our laboratory. The scanning fields of view of the EID and PCD at the isocenter are 500 and 275 mm, respectively. When objects are larger than the PCD scanning field of view, a data-completion scan (DCS) using the EID subsystem is needed to avoid truncation artifacts in PCD images. The goals of this work were to (1) find the impact...
37 CitationsSource
#1Ralf Gutjahr (TUM: Technische Universität München)H-Index: 7
#2Ahmed F. HalaweishH-Index: 16
Last. Cynthia H. McColloughH-Index: 76
view all 10 authors...
ObjectivesThe purpose of this work was to measure and compare the iodine contrast-to-noise ratio (CNR) between a commercial energy-integrating detector (EID) computed tomography (CT) system and a photon-counting detector (PCD) CT scanner capable of human imaging at clinical dose rates, as well as to
111 CitationsSource
#1Zhicong Yu (Mayo Clinic)H-Index: 11
#2Shuai Leng (Mayo Clinic)H-Index: 53
Last. Cynthia H. McCollough (Mayo Clinic)H-Index: 76
view all 11 authors...
This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for wa...
140 CitationsSource
#1Zhicong Yu (Mayo Clinic)H-Index: 11
#2Shuai Leng (Mayo Clinic)H-Index: 53
Last. Cynthia H. McCollough (Mayo Clinic)H-Index: 76
view all 11 authors...
X-ray computed tomography (CT) with energy-discriminating capabilities presents exciting opportunities for increased dose efficiency and improved material decomposition analyses. However, due to constraints imposed by the inability of photon-counting detectors (PCD) to respond accurately at high photon flux, to date there has been no clinical application of PCD-CT. Recently, our lab installed a research prototype system consisting of two x-ray sources and two corresponding detectors, one using a...
27 CitationsSource
#1J. Paul Ronaldson (University of Otago)H-Index: 3
#2Rafidah Zainon (Cant.: University of Canterbury)H-Index: 9
Last. Nigel G. Anderson (University of Otago)H-Index: 25
view all 7 authors...
Purpose: To determine the potential of spectral computed tomography (CT) with Medipix3 for quantifying fat, calcium, and iron in soft tissues within small animal models and surgical specimens of diseases such as fatty liver (metabolic syndrome) and unstable atherosclerosis. Methods: The spectroscopic method was applied to tomographic data acquired using a micro-CT system incorporating a Medipix3 detector array with silicon sensor layer and microfocus x-ray tube operating at 50 kVp. A 10 mm diame...
68 CitationsSource
#1Sang Chol Lee (SKKU: Sungkyunkwan University)H-Index: 1
#2Chad L. Carr (OHSU: Oregon Health & Science University)H-Index: 8
Last. Jonathan R. Lindner (OHSU: Oregon Health & Science University)H-Index: 77
view all 8 authors...
Objectives We sought to determine whether contrast-enhanced ultrasound (CEU) microangiography with maximum intensity projection (MIP) processing could temporally evaluate proliferation of the vasa vasorum (VV) in a model of mural hemorrhage. Background Expansion of the VV and plaque neovascularization contributes to plaque growth and instability and may be triggered by a variety of stimuli, including vascular hemorrhage. However, quantitative in vivo methods for temporal assessment of VV remodel...
21 CitationsSource
#1Erik L. Ritman (Mayo Clinic)H-Index: 77
#2Amir Lerman (Mayo Clinic)H-Index: 128
The function of vasa vasorum is both to deliver nutrients and oxygen to arterial and venous walls and to remove “waste” products, either produced by cells in the wall or introduced by diffusional transport through the endothelium of the artery or vein. Although the relationship between changes in vasa vasorum characteristics and the development of atheromatous plaques is well documented, the role of vasa vasorum, especially in terms of their appearance and disappearance in disease processes such...
176 CitationsSource
#1Seymour Glagov (U of C: University of Chicago)H-Index: 66
#2Elliot WeisenbergH-Index: 5
Last. George J. KolettisH-Index: 2
view all 5 authors...
Abstract Whether human coronary arteries undergo compensatory enlargement in the presence of coronary disease has not been clarified. We studied histologic sections of the left main coronary artery in 136 hearts obtained at autopsy to determine whether atherosclerotic human coronary arteries enlarge in relation to plaque (lesion) area and to assess whether such enlargement preserves the cross-sectional area of the lumen. The area circumscribed by the internal elastic lamina (internal elastic lam...
3,187 CitationsSource
Cited By2
Newest
#1Tania Pereira (University of Lleida)H-Index: 8
#2Àngels Betriu (Hospital Universitari Arnau de Vilanova)H-Index: 18
Last. Rui Alves (University of Lleida)H-Index: 29
view all 3 authors...
Abstract Carotid adventitia vasa vasorum neovascularization (VVn) is associated with the initial stages of arteriosclerosis and with the formation of unstable plaque. However, techniques to accurately quantify that neovascularization in a standard, fast, non-invasive, and efficient way are still lacking. The development of such techniques holds the promise of enabling wide, inexpensive, and safe screening programs that could stratify patients and help in personalized preventive cardiovascular me...
5 CitationsSource
#1Johoon Kim (UPenn: University of Pennsylvania)H-Index: 8
#2Daniel Bar-Ness (French Institute of Health and Medical Research)H-Index: 9
Last. David P. Cormode (UPenn: University of Pennsylvania)H-Index: 53
view all 7 authors...
Spectral photon-counting computed tomography (SPCCT) is a rapidly emerging imaging modality that provides energy-dependent information on individual x-ray photons, leading to accurate material decomposition and simultaneous quantification of multiple contrast generating materials. Development of SPCCT-specific contrast agents is needed to overcome the issues with currently used iodinated contrast agents, such as difficulty in differentiation from calcified structures, and yield SPCCT’s full prom...
31 CitationsSource