In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems

Published on Jun 1, 2017in Journal of Prosthetic Dentistry2.444
· DOI :10.1016/J.PROSDENT.2016.09.011
Tamer A. Hamza9
Estimated H-index: 9
(Misr International University),
Rana M. Sherif2
Estimated H-index: 2
(Cairo University)
Sources
Abstract
Abstract Statement of problem Dental laboratories use different computer-aided design and computer-aided manufacturing (CAD-CAM) systems to fabricate fixed prostheses; however, limited evidence is available concerning which system provides the best marginal discrepancy. Purpose The purpose of this in vitro study was to evaluate the marginal fit of 5 different monolithic zirconia restorations milled with different CAD-CAM systems. Material and methods Thirty monolithic zirconia crowns were fabricated on a custom-designed stainless steel die and were divided into 5 groups according to the type of monolithic zirconia crown and the CAD-CAM system used: group TZ, milled with an MCXL milling machine; group CZ, translucent zirconia milled with a motion milling machine; group ZZ, zirconia milled with a dental milling unit; group PZ, translucent zirconia milled with a zirconia milling unit; and group BZ, solid zirconia milled using an S1 VHF milling machine. The marginal fit was measured with a binocular microscope at an original magnification of ×100. The results were tabulated and statistically analyzed with 1-way ANOVA and post hoc surface range test, and pairwise multiple comparisons were made using Bonferroni correction (α=.05). Results The type of CAD-CAM used affected the marginal fit of the monolithic restoration. The mean (±SD) highest marginal discrepancy was recorded in group TZI at 39.3 ±2.3 μm, while the least mean marginal discrepancy was recorded in group IZ (22.8 ±8.9 μm). The Bonferroni post hoc test showed that group TZI was significantly different from all other groups tested ( P Conclusions Within the limitation of this in vitro study, all tested CAD-CAM systems produced monolithic zirconia restorations with clinically acceptable marginal discrepancies; however, the CAD-CAM system with the 5-axis milling unit produced the best marginal fit.
📖 Papers frequently viewed together
39 Citations
2 Citations
163 Citations
References36
Newest
#1Roberto Sorrentino (UNISI: University of Siena)H-Index: 23
#2Clementina Triulzio (UNISI: University of Siena)H-Index: 1
Last. Marco Ferrari (UNISI: University of Siena)H-Index: 100
view all 6 authors...
Abstract Objectives To compare the fracture resistance and mode of failure of CAD–CAM monolithic zirconia crowns with different occlusal thickness. Material and methods Forty CAD–CAM monolithic zirconia crowns with different occlusal thickness were randomly distributed into 4 experimental groups: 2.0 mm (group 1), 1.5 mm (group 2), 1.0 mm (group 3) and 0.5 mm (group 4). The restorations were cemented onto human molars with a self-adhesive resin cement. The specimens were loaded until fracture; t...
44 CitationsSource
#1Gabriel Kalil Rocha Pereira (UFSM: Universidade Federal de Santa Maria)H-Index: 19
#2T. Silvestri (UFSM: Universidade Federal de Santa Maria)H-Index: 5
Last. L.F. Valandro (UFSM: Universidade Federal de Santa Maria)H-Index: 3
view all 7 authors...
This study aimed to investigate the effects of grinding with diamond burs and low-temperature aging on the mechanical behavior (biaxial flexural strength and structural reliability), surface topography, and phase transformation of a Y-TZP ceramic for monolithic dental restorations. Disc-shaped specimens (Zirlux FC, Ivoclar Vivadent) were manufactured according to ISO 6872 (2008) and divided in accordance with two factors: “grinding — 3 levels” and “LTD — 2 levels”. Grinding was performed using a...
46 CitationsSource
Abstract Zirconia crowns combine the advantages of metal restorations, such as minimally invasive tooth preparation and ease of cementation, with those of full ceramic crowns, such as low thermal conductivity and tooth color. With the introduction of a high-speed sintering procedure, it is possible to produce and cement zirconia crowns and small monolithic bridges in a Cerec Single Visit procedure. This new procedure is compared to established chairside methods.
7 Citations
#1Christian F. Selz (University of Freiburg)H-Index: 5
#2Jan Bogler (University of Freiburg)H-Index: 1
Last. Petra C. Guess (University of Freiburg)H-Index: 26
view all 5 authors...
Abstract Objectives The aim of this prospective clinical study was to evaluate the clinical performance of veneered anatomically designed zirconia fixed dental prostheses (FDPs) resulting from intraoral digital impressions. Methods 24 patients requiring treatment were provided with all-ceramic FDPs. Intraoral scans (iTero) were performed and veneered anatomically designed CAD/CAM-zirconia FDPs (Zerion/VitaVM9) were fabricated. A feldspar veneering ceramic following a slow cooling firing protocol...
13 CitationsSource
#1Fumiyori Matsuzaki (Tokyo Dental College)H-Index: 2
#2Hideshi Sekine (Ohu University)H-Index: 7
Last. Masao Yoshinari (Tokyo Dental College)H-Index: 46
view all 7 authors...
This study aims to investigate the effectiveness of monolithic translucent TZP with different colors and porcelain-layered TZP by evaluating their colors and strengths. Different mixing ratios of Zpex to Zpex-Yellow as translucent TZP, conventional opaque TZP (TZ-3YB-E) (Tosoh, Tokyo) as a control, and veneering porcelain (CERABIEN ZR, body porcelain, Noritake, Tokyo) with shade A3 as a typical shade. Disk-shaped specimens of 13 mm diameter and 1.5 mm thickness were prepared. These specimens wer...
47 CitationsSource
#1Taiseer A. Sulaiman (UNC: University of North Carolina at Chapel Hill)H-Index: 9
#2Aous A. Abdulmajeed (UTU: University of Turku)H-Index: 5
Last. Lippo V.J. Lassila (UTU: University of Turku)H-Index: 70
view all 7 authors...
Abstract Objectives The aims of this study were to: (1) estimate the effect of polishing on the surface gloss of monolithic zirconia, (2) measure and compare the translucency of monolithic zirconia at variable thicknesses, and (3) determine the effect of zirconia thickness on irradiance and total irradiant energy. Methods Four monolithic partially stabilized zirconia (PSZ) brands; Prettau® (PRT, Zirkonzahn), Bruxzir® (BRX, Glidewell), Zenostar® (ZEN, Wieland), Katana® (KAT, Noritake), and one fu...
81 CitationsSource
#1Ji Suk Shim (KU: Korea University)H-Index: 6
#2Jin Sook Lee (KU: Korea University)H-Index: 1
Last. Jae Jun Ryu (KU: Korea University)H-Index: 15
view all 6 authors...
Objective This study investigated the marginal and internal adaptation of individual dental crowns fabricated using a CAD/CAM system (Sirona’s BlueCam), also evaluating the effect of the software version used, and the specific parameter settings in the adaptation of crowns.Material and Methods Forty digital impressions of a master model previously prepared were acquired using an intraoral scanner and divided into four groups based on the software version and on the spacer settings used. The vers...
35 CitationsSource
#1Balasudha Baladhandayutham (UR: University of Rochester)H-Index: 1
#2Nathaniel C. Lawson (UAB: University of Alabama at Birmingham)H-Index: 19
Last. John O. Burgess (UAB: University of Alabama at Birmingham)H-Index: 33
view all 3 authors...
Abstract Statement of problem A clinician must decide what ceramic coping and veneer material to prescribe based on the amount of tooth reduction possible and the desired esthetic outcome of the restoration. Purpose The purpose of this in vitro study was to compare the fracture strength of monolithic and bilayered lithium disilicate (IPS e.max) and zirconia (LAVA) crowns at clinically relevant thicknesses after load cycling. Material and methods Crowns (n=8) were fabricated from 6 groups: 1.2-mm...
27 CitationsSource
#1Nicoleta Ilie (LMU: Ludwig Maximilian University of Munich)H-Index: 38
#2Bogna Stawarczyk (LMU: Ludwig Maximilian University of Munich)H-Index: 47
Abstract Statement of problem Dual-polymerized luting composite resin cements would benefit from enhanced irradiance transmitted through a ceramic restoration. A quantification of the amount of transmitted light through translucent zirconia is lacking. Purpose The purpose of this study was to evaluate the amount of light (360 to 540 nm) passing through translucent and conventional zirconia and a glass ceramic with respect to material thickness and different polymerizing modes. Material and metho...
41 CitationsSource
Abstract As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the ...
27 Citations
Cited By27
Newest
#1Ting-Hsun LanH-Index: 8
Last. Mitch M.C. ChouH-Index: 17
view all 4 authors...
The computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication technique has become one of the hottest topics in the dental field. This technology can be applied to fixed partial dentures, removable dentures, and implant prostheses. This study aimed to evaluate the feasibility of NaCaPO4-blended zirconia as a new CAD/CAM material. Eleven different proportional samples of zirconia and NaCaPO4 (xZyN) were prepared and characterized by X-ray diffractometry (XRD) and Vickers microhardn...
Source
#1Hyun-Wook Kim (Ewha Womans University)
#2Ha-Kyung Song (Ewha Womans University)
Last. Eun-Jin Park (Ewha Womans University)H-Index: 13
view all 3 authors...
Source
#1Alexis Ioannidis (UZH: University of Zurich)H-Index: 11
#2Ji-Man Park (Yonsei University)H-Index: 14
Last. Mutlu Özcan (UZH: University of Zurich)H-Index: 72
view all 6 authors...
Abstract Statement of problem Whether additively produced zirconia could overcome problems with conventional computer-aided design and computer-aided manufacture (CAD-CAM) such as milling inaccuracies and provide accurate occlusal veneers is unclear. Purpose The purpose of this in vitro study was to compare the marginal and internal fit of 3D-printed zirconia occlusal veneers with CAD-CAM–fabricated zirconia or heat-pressed lithium disilicate ceramic (LS2) restorations on molars. Material and me...
Source
PURPOSE To compare the marginal fit and internal surface roughness of CAD/CAM zirconia copings milled with 3- and 5-axis milling devices. MATERIALS AND METHODS Forty titanium implant stock abutments (4.8 mm in diameter, 4 mm in height) screwed to dental implants (4.1 mm in diameter) embedded in resin were considered phantoms and included in this in vitro study. All 40 phantoms were scanned with the same intraoral scanner, from which images of the virtual wax-up of zirconia copings were obtained ...
Source
Abstract Statement of problem Information on the fabrication of metal by selective laser melting (SLM) systems positioned at different angles is sparse. Purpose The purpose of this in vitro study was to evaluate the extent of marginal and internal gaps in metal copings fabricated at different angles by using an SLM fabrication system. Material and methods A master metal model was produced and replicated (N=10) with silicone impressions and dental stone. Standard tessellation language (STL) files...
Source
#1Maria Del Piñal (UFSC: Universidade Federal de Santa Catarina)
#2Carlos Lopez-Suarez (Complutense University of Madrid)H-Index: 7
Last. Maria J Suarez (Complutense University of Madrid)H-Index: 14
view all 5 authors...
Abstract Statement of problem Marginal fit of zirconia restorations is an important criterion for their long-term success. However, in spite of the wide use of zirconia in dentistry, the relationship between marginal fit and low-temperature degradation from aging is unclear. Purpose The purpose of this in vitro study was to compare the marginal adaptation of veneered and monolithic zirconia and metal-ceramic computer-aided design and computer-aided manufacturing (CAD-CAM) crowns before and after...
Source
#1Maria Rizonaki (UGent: Ghent University)
#2Wolfgang JacquetH-Index: 14
Last. Peter De Coster (UGent: Ghent University)H-Index: 11
view all 6 authors...
Abstract Statement of problem Whether the precision of fit of computer-aided design and computer-aided manufacturing (CAD-CAM) complete crowns is affected by the finish line configuration is unclear. Purpose The purpose of this in vitro study was to evaluate the marginal and internal fit of CAD-CAM ceramic crowns made from lithium disilicate based on 3 different finish lines (rounded shoulder, chamfer, feather-edge). Materials and methods Thirty anterior lithium disilicate complete crowns (n=10 ...
Source
#1Yolanda Freire (Complutense University of Madrid)H-Index: 1
#2Esther Gonzalo (Complutense University of Madrid)H-Index: 9
Last. Maria J Suarez (Complutense University of Madrid)H-Index: 14
view all 5 authors...
Purpose To evaluate the influence of intraoral and extraoral digitization systems on marginal discrepancy of monolithic lithium disilicate and monolithic zirconia computer-aided design-computer-aided manufacturing (CAD-CAM) crowns. Methods Forty standardized machined stainless steel specimens with the characteristics of a first molar were manufactured and randomly assigned to two groups (n=20 each), depending on their material: monolithic lithium disilicate ceramic (LM), and monolithic zirconia ...
Source
objective. to conclude clinically, if endocrowns are a dependable substitute to post-retained restorations for significantly broken endodontically treated teeth and which restorative materials are proficient customized for constructing endocrowns. Material and methods. The clinical study is an open label, parallel groups conducted randomly at Assiut University Dental Hospital. The trial involved a total of 40 patients. After providing signed informed consent, patients are enrolled and classified...
Source
Source