Dosimetric comparison of intensity modulated pelvic radiotherapy with 3D conformal radiotherapy in patients with gynecologic malignancies.

Volume: 30, Issue: 5, Pages: 547 - 51
Published: Jan 1, 2009
Abstract
Before initiating an intensity modulated radiotherapy (IMRT) program for gynecologic malignancies we prospectively evaluated the potential benefits of IMRT by dose volume histogram comparison of IMRT and 3D conformal radiotherapy plans.Plans of ten consecutive patients with cervical and endometrial cancer were evaluated. For each patient a 4-field box technique was compared to an IMRT plan. Both plans were normalized to deliver 50.4 Gy to the...