Comparison of effective doses obtained from dose–area product and air kerma measurements in interventional radiology

Volume: 77, Issue: 916, Pages: 315 - 322
Published: Apr 1, 2004
Abstract
In this study, measurements of dose-area product (DAP) and entrance dose were carried out simultaneously in a sample of 162 adult patients who underwent different interventional examinations. Effective doses for each measurement technique were estimated using the conversion factors that have been determined for specific X-ray views in a mathematical phantom. Exposure conditions used in clinical practice never match these theoretical models...
Paper Details
Title
Comparison of effective doses obtained from dose–area product and air kerma measurements in interventional radiology
Published Date
Apr 1, 2004
Volume
77
Issue
916
Pages
315 - 322