Survey of practice in paediatric computed tomography.

Published on Sep 1, 2011in Radiation Protection Dosimetry0.773
· DOI :10.1093/RPD/NCR327
D. Kostova-Lefterova4
Estimated H-index: 4
,
Jenia Vassileva15
Estimated H-index: 15
Sources
Abstract
The purpose of this study was to explore the frequency of paediatric computed tomography (CT) examinations in several hospitals in Bulgaria and to assess the current practice. The standard forms provided by the International Atomic Emergency Agency for survey of the paediatric CT practice were used. Six hospitals provided data on frequency of paediatric CT examinations performed in 2009. Large variations in dose, up to a factor of 4, were found among the centres within the same age group for a given procedure, and in one of the hospitals the paediatric dose was twice higher than the adult dose. Seven departments use dedicated CT protocols for children. Only 4 in 12 departments keep records of patient dose. Dose information for previous examinations is not required by the radiologists. The collected detailed data provided preliminary information how the patient doses in paediatric CT can be reduced. Recommendations were given based on the findings.
📖 Papers frequently viewed together
2 Citations
5 Citations
12 Citations
References2
Newest
#1Keith J. Strauss (Boston Children's Hospital)H-Index: 33
#2Marilyn J. GoskeH-Index: 24
Last. Kimberly E. ApplegateH-Index: 49
view all 9 authors...
AJR:194, April 2010 This article suggests 10 steps that radiologists and radiologic technologists, with the assistance of their medical physicist, can take to obtain good quality CT images while properly managing radiation dose for children undergoing CT. The first six steps ideally should be completed before performing any CT on a pediatric patient. The final four steps address the unique consideration that should be given for each scanned patient.
216 CitationsSource
#1David J. Brenner (Columbia University)H-Index: 87
#2Carl D. EllistonH-Index: 16
Last. Walter E. BerdonH-Index: 55
view all 4 authors...
OBJECTIVE. In light of the rapidly increasing frequency of pediatric CT examinations, the purpose of our study was to assess the lifetime cancer mortality risks attributable to radiation from pediatric CT.MATERIALS AND METHODS. Organ doses as a function of age-at-diagnosis were estimated for common CT examinations, and estimated attributable lifetime cancer mortality risks (per unit dose) for different organ sites were applied. Standard models that assume a linear extrapolation of risks from int...
2,500 CitationsSource
Cited By4
Newest
#1Joana Santos (IPN: Instituto Politécnico Nacional)H-Index: 3
#2Shane Foley (UCD: University College Dublin)H-Index: 11
Last. Louise Rainford (UCD: University College Dublin)H-Index: 15
view all 5 authors...
Background The volume of CT examinations has increased with resultant increases in collective dose values over the last decade.
6 CitationsSource
#1Olivera Ciraj-Bjelac (University of Belgrade)H-Index: 14
#2M. R. Gavrilović (University of Belgrade)H-Index: 5
Last. Predrag Bozovic (University of Belgrade)H-Index: 2
view all 5 authors...
: Objective of this work is to evaluate radiation exposure from X-ray examinations in a large paediatric hospital in Serbia, including radiographic, fluoroscopic and computed tomography (CT) examinations in four age groups: 0-1, 1-5, 5-10 and 10-15 y. Incident air kerma was assessed for the following radiographies: chest (AP, PA, LAT), spine (AP, LAT), pelvis (AP), urinary tract (AP, PA) and skull (AP, PA, LAT). Kerma-area product was measured for the fluoroscopy examinations: barium swallow, ba...
4 CitationsSource
#1Joana Santos (IPN: Instituto Politécnico Nacional)H-Index: 3
Last. Louise Rainford (UCD: University College Dublin)H-Index: 15
view all 6 authors...
: The purpose of the study is to perform phantom-based optimisation of paediatric computed tomography (CT) protocols and quantify the impact upon radiation dose and image noise levels. The study involved three Portuguese paediatric centres. Currently employed scanning protocols for head and chest examinations and combinations of exposure parameters were applied to a Catphan(®)600 phantom to review the CT dose impact. Contrast-noise ratio (CNR) was quantified using Radia Diagnostic(®) tool. Imagi...
5 CitationsSource
#1Keith J. Strauss (Boston Children's Hospital)H-Index: 33
#2Marilyn J. GoskeH-Index: 24
Last. Kimberly E. ApplegateH-Index: 49
view all 9 authors...
AJR:194, April 2010 This article suggests 10 steps that radiologists and radiologic technologists, with the assistance of their medical physicist, can take to obtain good quality CT images while properly managing radiation dose for children undergoing CT. The first six steps ideally should be completed before performing any CT on a pediatric patient. The final four steps address the unique consideration that should be given for each scanned patient.
216 CitationsSource