Comparison of detection of F-18 fluorodeoxyglucose positron emission tomography and 99mTc-hexamethylpropylene amine oxime labelled leukocyte scintigraphy for an aortic graft infection

Volume: 10, Issue: 1, Pages: 142 - 143
Published: Jan 1, 2010
Abstract
To compare F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG-PET) and (99m)Tc-hexamethylpropylene amine oxime ((99m)TC-HMPAO) labelled leukocyte scintigraphy for the diagnosis of vascular graft infection. A thoraco-abdominal CT-angiography and a (99m)TC-HMPAO labelled leukocyte scintigraphy did not show any graft infection in this case report whereas an F-18 FDG-PET showed a metabolic uptake around and all along the vascular graft....