Seismic Analysis Study of the HP Turbine Steam Supply Piping for APR1400

Published: Jan 1, 2010
Abstract
The high pressure (HP) turbine steam supply piping for APR1400 (Korea’s advanced power reactor 1400 MW-class) is routed from the Containment Building to the Turbine building via the Main Steam Isolation Valve Room in the Auxiliary building and supported by multiple structures. As such, the seismic analysis utilizing the Independent Support Motion (ISM) is preferable to the Enveloped Response Spectrum (ERS) method which is overly conservative but...
Paper Details
Title
Seismic Analysis Study of the HP Turbine Steam Supply Piping for APR1400
Published Date
Jan 1, 2010
Citation AnalysisPro
  • Scinapse’s Top 10 Citation Journals & Affiliations graph reveals the quality and authenticity of citations received by a paper.
  • Discover whether citations have been inflated due to self-citations, or if citations include institutional bias.