Factors Influencing Response to Strabismus Surgery
Abstract
Based on analyses in a series of 116 patients, we found that the response to strabismus surgery (degrees of change of ocular alignment per millimeter of rectus recession) correlated significantly with the preoperative deviation for esotropic and exotropic patients. The prediction of response to strabismus surgery was not improved significantly with the inclusion of axial length, age, and/or preoperative refractive error beyond the prediction...
Paper Details
Title
Factors Influencing Response to Strabismus Surgery
Published Date
Jan 1, 1993
Journal
Volume
111
Issue
1
Pages
75 - 75