A comparison of radiation dose between standard and 3D angiography in congenital heart disease.

Published on Aug 1, 2014in Arquivos Brasileiros De Cardiologia1.45
· DOI :10.5935/ABC.20140118
João Luiz Manica12
Estimated H-index: 12
,
Mônica Scott Borges2
Estimated H-index: 2
+ 3 AuthorsRaul Ivo Rossi Filho4
Estimated H-index: 4
Sources
Abstract
Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.
📖 Papers frequently viewed together
41 Citations
104 Citations
19 Citations
References19
Newest
#1Victor Grech (University of Malta)H-Index: 22
#2Marvin Grech (Mater Dei Hospital)H-Index: 2
Last. Albert Fenech (Mater Dei Hospital)H-Index: 4
view all 5 authors...
8 CitationsSource
#1Benjamin G. Smith (Boston Children's Hospital)H-Index: 4
#2Shane M. Tibby (Boston Children's Hospital)H-Index: 37
Last. Thomas Krasemann (Boston Children's Hospital)H-Index: 15
view all 5 authors...
Purpose To quantify the impact of relocation to a purpose built pediatric cardiac catheterization laboratory, on patient radiation dose and fluoroscopy time. To provide guide values for radiation exposure during common structural interventions. Material and methods Design: A retrospective review of common structural cardiac interventions performed over 10-years. The era comprised two 5-year periods before and after relocation using different catheter laboratories. Multivariable analysis adjusted...
24 CitationsSource
#1Darren P. Berman (Boston Children's Hospital)H-Index: 9
#2Danyal Khan (Boston Children's Hospital)H-Index: 10
Last. Evan M. Zahn (Boston Children's Hospital)H-Index: 34
view all 4 authors...
Background Bi-plane angiography is the gold standard for imaging the pulmonary arteries (PAs) after cavo-pulmonary connection (CPC). Three-dimensional rotational angiography (3DRA) is emerging technology that we hypothesized may enhance diagnostic capabilities in this patient group. Methods Retrospective review of patients who underwent 3DRA to assess the PAs after CPC. 3DRA images were examined for diagnostic quality and compared, both qualitatively and quantitatively with corresponding 2D imag...
41 CitationsSource
#1Marvin Grech (Mater Dei Hospital)H-Index: 2
#2Joseph Debono (Mater Dei Hospital)H-Index: 3
Last. Victor Grech (Mater Dei Hospital)H-Index: 22
view all 5 authors...
Background: Coronary angiography remains the gold standard for the investigation of coronary artery disease, and is carried out in multiple, predefined stationary views, at different angulations around the patient, for both left and right coronary arteries. Dual axis rotational coronary angiography (DARA) is an alternative technique wherein the c-arm rotates around the patient in a preprogrammed single acquisition, exposing the entire coronary artery at different angulations. The DARA system has...
24 CitationsSource
#1Maiy El Sayed (Ain Shams University)H-Index: 2
#2Alaa Roushdy (Ain Shams University)H-Index: 6
Last. Ahmad El Sherbini (NIH: National Institutes of Health)H-Index: 1
view all 4 authors...
Cardiac catheterizations are among the X-ray procedures with the highest patient radiation dose and therefore are of great concern in pediatric settings. This study aimed to evaluate factors that influence variability of X-ray exposure in children with congenital heart diseases during cardiac catheterization. The study included 107 children who underwent either diagnostic (n = 46) or interventional (n = 61) procedures. A custom-made sheet for patient and procedural characteristics was designed. ...
33 CitationsSource
#1Martin GlöcklerH-Index: 11
#2Andreas KochH-Index: 24
Last. Sven DittrichH-Index: 25
view all 8 authors...
Objectives To analyse the diagnostic utility of flat-detector computed tomography imaging (FD-CT) in patients with congenital heart disease, including the value of image fusion to overlay three-dimensional (3D) reconstructions on fluoroscopic images during catheter-based interventions.
25 CitationsSource
#1Charles E. Chambers (PSU: Pennsylvania State University)H-Index: 34
#2Kenneth A. Fetterly (Mayo Clinic)H-Index: 18
Last. Warren K. Laskey (UNM: University of New Mexico)H-Index: 49
view all 7 authors...
The Society of Cardiovascular Angiography and Interventions present a practical approach to assist cardiac catheterization laboratories in establishing a radiation safety program. The importance of this program is emphasized by the appropriate concerns for the increasing use of ionizing radiation in medical imaging, and its potential adverse effects. An overview of the assessment of radiation dose is provided with a review of basic terminology for dose management. The components of a radiation s...
226 CitationsSource
#1Andrew C. Glatz (UPenn: University of Pennsylvania)H-Index: 30
#2Xiaowei Zhu (UPenn: University of Pennsylvania)H-Index: 13
Last. Jonathan J. Rome (UPenn: University of Pennsylvania)H-Index: 56
view all 5 authors...
Objectives This study sought to retrospectively evaluate our initial experience using angiographic computed tomography (ACT) in a pediatric cardiac catheterization laboratory. Background ACT provides cross-sectional CT images from a rotational angiography run using a C-arm mounted flat-panel detector in the interventional suite. A 3-dimensional (3D) angiographic image can be created from the CT volume set and used in real time during the procedure. To our knowledge, its use has never previously ...
104 CitationsSource
#1Carlos Eduardo Bernini Kapins (UNIFESP: Federal University of São Paulo)H-Index: 4
#2Ralph Bittencourt Coutinho (UNIFESP: Federal University of São Paulo)H-Index: 1
Last. Antonio Carlos Carvalho (UNIFESP: Federal University of São Paulo)H-Index: 54
view all 6 authors...
BACKGROUND: Advances in the diagnosis and treatment of congenital heart disease are associated to advances in imaging techniques. Anatomic images obtained by computed tomography scan, magnetic resonance imaging (MRI) and echocardiography have been useful but cannot provide accurate hemodynamic data. 3D rotational angiography (3D-RA) is a new 3D reconstruction method carried out in the cath lab that has been widely used in neurological and urological procedures. This study was aimed at evaluating...
10 CitationsSource
#1Pierfrancesco Agostoni (Cardiovascular Institute of the South)H-Index: 59
#2Giuseppe Biondi-Zoccai (UNITO: University of Turin)H-Index: 102
Last. Stefan Verheye (Cardiovascular Institute of the South)H-Index: 17
view all 10 authors...
Vessel foreshortening is a major limitation of standard coronary angiography due to the 2-dimensional representation of 3-dimensional structures. Three-dimensional models may overcome it. The aim of this study was to compare measurements of coronary segments from quantitative coronary angiography (QCA) in an operator-selected "working view" of standard 2-dimensional coronary angiography with those from 3-dimensional coronary angiography (3D-CA) reconstruction models, which are automatically gene...
51 CitationsSource
Cited By13
Newest
#2Sebastian Góreczny (Jagiellonian University Medical College)
Abstract Pediatric cardiology is eminently dependent on imaging for the accurate diagnosis and treatment of congenital and structural heart disease. The understanding of the three-dimensionality of the normal and pathological inner structures of the heart, their dynamic spatial inter-relationships and the influences on flow are critical to planning and performing interventions. Advances in computer technology have made three-dimensional reconstructions readily available and the quality of these ...
Source
#1Kenneth A. Fetterly (Mayo Clinic)H-Index: 18
#2Andrea Ferrero (Mayo Clinic)H-Index: 8
Last. Nathaniel W. Taggart (Mayo Clinic)H-Index: 14
view all 6 authors...
Objectives The purpose of this study was to investigate the influence of simulated reduced-dose three-dimensional angiography (3DA) on the accuracy and precision of linear measurements derived from 3DA datasets. Background Three-dimensional angiography is performed during X-ray guided interventional procedures to aid diagnosis and inform treatment strategies for children and adults with congenital heart disease. However, 3DA contributes substantially to patient radiation dose and may lead to an ...
Source
#1Stefanie SöderH-Index: 1
#2Wolfgang WällischH-Index: 1
Last. Martin Glöckler (University of Bern)H-Index: 11
view all 6 authors...
This paper aims to assess the usability and advantages of three-dimensional rotational angiography (3DRA) in patients with congenital heart disease (CHD) and its application in the cath lab. Up to now, its use in CHD is not widespread or standardized. We analyzed all patients with CHD who underwent a 3DRA at our facility between January 2010 and May 2019. The 3DRAs were evaluated for radiation exposure, contrast dye consumption, diagnostic utility and image quality. We performed 872 3DRAs. 3DRA ...
1 CitationsSource
#1Luca GiugnoH-Index: 5
#2Alessia FacciniH-Index: 4
Last. Mario CarminatiH-Index: 39
view all 3 authors...
Percutaneous pulmonary valve implantation (PPVI) is recognized as a feasible and low risk alternative to surgery to treat dysfunctional right ventricular outflow tract (RVOT) in usually pluri-operated patients. Evolving technology allowed to develop different kind of prosthesis and to go from an initial treatment exclusively of stenotic conduit to an actual approach extended also to wide native RVOT. The Melody transcatheter pulmonary valve (TPV) and the Edwards Sapien valve are nowadays the mos...
1 CitationsSource
#1Sebastian Góreczny (Memorial Hospital of South Bend)H-Index: 10
#2Evan M. Zahn (Cedars-Sinai Medical Center)H-Index: 34
The history of congenital interventional cardiology has seen numerous groundbreaking innovations typically related to the introduction of a new device or a novel treatment technique. Similarly, imaging of cardiac defects has changed dramatically over the past decades, although some of the advancements have seemed to omit the catheterisation laboratories. Rotational angiography, one of the imaging techniques for guidance of cardiac catheterisation currently referred to as "advanced", in fact was ...
1 CitationsSource
#1Sok-Leng Kang (U of T: University of Toronto)H-Index: 2
#2Aimee K. Armstrong (OSU: Ohio State University)H-Index: 10
Last. Lee N. Benson (U of T: University of Toronto)H-Index: 74
view all 4 authors...
: Three-dimensional rotational angiography (3D-RA) enables volumetric imaging through rotation of the C-arm of an angiographic system and real-time 3D reconstruction during cardiac catheterization procedures. In the field of congenital heart disease (CHD), 3D-RA has gained considerable traction, owing to its capability for enhanced visualization of spatial relationships in complex cardiac morphologies and real time image guidance in an intricate interventional environment. This review provides a...
3 CitationsSource
#1Femke van der Stelt (UU: Utrecht University)H-Index: 4
#2Sebastiaan N. Siegerink (UU: Utrecht University)H-Index: 1
Last. Johannes M.P.J. Breur (UU: Utrecht University)H-Index: 17
view all 5 authors...
Cardiac catheterization is a commonly used form of imaging and treatment in pediatric patients with congenital heart disease. Traditionally, two-dimensional conventional angiography was the method used, but since 2000 three-dimensional rotational angiography (3DRA) is increasingly used in the field of cardiology in both adult and pediatric patients. To investigate the use and applications of 3DRA in pediatric congenital cardiology, literature was systematically reviewed and 29 eligible articles ...
4 CitationsSource
#1Savine C. S. Minderhoud (UU: Utrecht University)H-Index: 1
#2Femke van der Stelt (UU: Utrecht University)H-Index: 4
Last. Johannes M.P.J. Breur (UU: Utrecht University)H-Index: 17
view all 6 authors...
Previously, median effective dose (ED) of 1.6 mSv per three-dimensional rotational angiography (3DRA) has been reported. This study evaluated ED and image quality in 3DRA after implementation of a simple dose reduction protocol in pediatric catheterizations. Simple conversion factors between 3DRA ED and readily available parameters at the cathlab were determined. The dose reduction protocol consisted of frame reduction (60–30 frames/s (f/s)), active collimation of the X-ray beam, usage of a read...
4 CitationsSource
#1Sok-Leng Kang (U of T: University of Toronto)H-Index: 2
#2Lee N. Benson (U of T: University of Toronto)H-Index: 74
The field of pediatric and adult congenital cardiac catheterization has evolved rapidly in recent years. This review will focus on some of the newer endovascular technological and management strategies now being applied in the pediatric interventional laboratory. Emerging imaging techniques such as three-dimensional (3D) rotational angiography, multi-modal image fusion, 3D printing, and holographic imaging have the potential to enhance our understanding of complex congenital heart lesions for di...
7 CitationsSource
Source