Failure of Titanium Condenser Tubes After 24 Years Power Plant Service

Volume: 14, Issue: 5, Pages: 554 - 563
Published: Aug 26, 2014
Abstract
The titanium condenser has been in operation for 24 years at Amager unit 3 power plant. In February 2012, the plant was contaminated by seawater due to a failed condenser tube and some tubes were plugged. A month later, the plant tripped again. Small leaks were found again and finally approx. 200 tubes were plugged before the condenser was in service again. A series of inspections, NDT, and destructive examinations were conducted to try and...