Stress corrosion cracking of the pre-immersed tin brass heat exchanger tube in an ammoniacal solution

Published on Feb 28, 2013in Materials & Design6.289
· DOI :10.1016/J.MATDES.2013.09.015
Amjad Saleh El-Amoush5
Estimated H-index: 5
(University College of Engineering),
Ayman Zamil1
Estimated H-index: 1
(University College of Engineering)
+ 1 AuthorsNidal Ismail1
Estimated H-index: 1
(University College of Engineering)
Sources
Abstract
Abstract The stress corrosion cracking (SCC) of the pre-immersed tin brass heat exchanger tube was investigated using slow strain rate testing (SSRT) in an environment containing ammonia. Tubular specimens were exposed at room temperature to this environment for different time prior to straining. The brass tube operated for longer time exhibited more severe SSC cracking and larger dezincified area than that of the tube operated for shorter time. Intergranular SSC was observed in the fracture surface of the specimen pre-immersed for short time, whereas both intergranular and transgranular SCC were observed at the fracture surface of the specimen pre-immersed for longer time. Furthermore, many pits were observed in the fracture surface of the material. A dezincification had occurred after SSRT and the severity of a dezincified area through the tube is depended on the pre-immersion conditions applied to tube. Stress–strain diagrams showed a decrease in tensile properties of the tin brass tube due to the formation of SCC. Remarkable decrease of the ultimate tensile strength (UTS) and fracture strain of tin brass specimens was found due to SCC.
📖 Papers frequently viewed together
3 Citations
2001
1 Author (Guo Xian)
1 Citations
References17
Newest
#1Shen Qu (CAS: Chinese Academy of Sciences)H-Index: 3
#1Shengchun Qu (CAS: Chinese Academy of Sciences)H-Index: 27
Last. Z.F. Zhang (CAS: Chinese Academy of Sciences)H-Index: 6
view all 4 authors...
Failure analysis was carried out on leaked brass tubes of a lubricating oil cooler. Direct evidences of dezincification and stress corrosion cracking (SCC) were observed by scanning electron microscope (SEM) and energy dispersive spectroscopic (EDS) analysis. It is found that there are many small pits distributed on the fracture surface and EDS analysis revealed the occurrence of dezincification in the small pits. SCC was observed on the cross-sectional plane of the fracture by SEM. Ammonia test...
4 CitationsSource
#1Carlo Mapelli (Polytechnic University of Milan)H-Index: 15
#2Andrea Gruttaduaria (Polytechnic University of Milan)H-Index: 1
Last. M. Bellogini (Polytechnic University of Milan)H-Index: 4
view all 3 authors...
Abstract Several electro-valves have failed because of the fracture occurred on the internal sleeve made in a typical free cutting leaded brass CW614 N (UNS 36000). The morphology of the observed fracture surface clearly indicates that the failure phenomenon has been ruled by a stress corrosion cracking mechanism. On the other hand, all the electro-valves operate in an environment featured by potable water that does not justify an alchaline concentration able to induce the SCC phenomenon. The an...
6 CitationsSource
#1Akram Alfantazi (UBC: University of British Columbia)H-Index: 33
#2Tawfik M. Ahmed (UBC: University of British Columbia)H-Index: 7
Last. Desmond Tromans (UBC: University of British Columbia)H-Index: 26
view all 3 authors...
Abstract The potentiodynamic polarization behavior of copper alloys in chloride solutions (1 M NaCl) of different pH’s (6.5 and 10) was investigated. Three commercial alloys of nominal composition Cu–30Ni (Cu–Ni), Cu–30Zn (Cu–Zn) and 90Cu–8Al–2Fe (Cu–Al) were considered. Results at pH of 6.5 showed no evidence of passivity with polarization behavior being dominated by the Cu component. At pH of 10, however, some evidence of limited passivity was seen. Passivity was more evident in buffered chlor...
116 CitationsSource
#1H.M. Shalaby (Kuwait Institute for Scientific Research)H-Index: 5
Abstract Failure investigation was carried out on corroded Muntz tubesheet and Ti tubes of a surface condenser. The Muntz metal was found to have suffered from corrosion grooves and micropits, which were crystallographic in nature. X-ray mapping revealed the occurrence of dezincification. The Ti tube ends suffered from separation and cracking of the deformed grains in addition to shallow localized attack. Corrosion of the Muntz metal was attributed to coupling with Ti, while corrosion of Ti was ...
11 CitationsSource
#1S.G Russo (DST: Defence Science and Technology Organisation)H-Index: 1
#2M.J Henderson (DST: Defence Science and Technology Organisation)H-Index: 1
Last. Bruce Hinton (DST: Defence Science and Technology Organisation)H-Index: 28
view all 3 authors...
Abstract Condensed moisture from ingressed humid air was responsible for inducing corrosion within the aft radar antenna from an RAAF P-3C Orion maritime surveillance aircraft. Porosity in the silver-plating of a flexible brass waveguide allowed moisture to penetrate to the brass substrate and cause dezincification. The moisture also induced corrosion of some of the AA-6061 aluminium alloy waveguides. An investigation determined that moisture ingress occurred at a waveguide flange, possibly from...
10 CitationsSource
#2G.S DuffóH-Index: 1
Last. J.R GalveleH-Index: 2
view all 3 authors...
Abstract The effect of strain rate (SR) on the stress corrosion crack propagation rate (CPR), for strain rates covering a wide range of values (10 −6 s −1 −1 ) was studied for numerous systems. The increase in the SR value was found to produce a monotonic increase in the CPR values. It was also observed that the accelerating effect of the SR was always higher for intergranular stress corrosion cracking (IGSCC) than for transgranular stress corrosion cracking (TGSCC). Typical slopes measured for ...
21 CitationsSource
#1Hong Lu (USTB: University of Science and Technology Beijing)H-Index: 3
#2Kewei Gao (USTB: University of Science and Technology Beijing)H-Index: 31
Last. Wuyang Chu (USTB: University of Science and Technology Beijing)H-Index: 27
view all 3 authors...
The brass foil with a protective layer formed on one side was deflected during original corrosion in 1 mol⧹L NH4OH+5 g⧹LCuCl2 solution. This was due to corrosion-induced tensile stress developed in the dezincification layer of the sample. The additive tensile stress grew gradually, and reached a steady value of about 24.4 MPa, i.e., 20% of the yield stress of brass.
47 CitationsSource
#1Linda GarverickH-Index: 1
136 Citations
11 Citations
#1Z. Xia (OSU: Ohio State University)H-Index: 9
#2Z. Szklarska-Smialowska (OSU: Ohio State University)H-Index: 20
Abstract The chemical composition and morphology of corrosion products accumulated on the internal surfaces of admiralty brass tubes and in pits, formed during service of a power plant condenser cooled with brackish water, were examined and compared with corrosion products formed under laboratory conditions simulating those in the plant. X-ray diffraction (XRD) was used for corrosion product analysis. Electrochemical tests were performed to characterize alloy corrosion behavior. In this way, con...
25 CitationsSource
Cited By5
Newest
#1Husaini Ardy (ITB: Bandung Institute of Technology)H-Index: 3
Last. Afriyanti Sumboja (ITB: Bandung Institute of Technology)H-Index: 29
view all 9 authors...
The surface condenser in the steam turbine plays an essential role during the condensation process. Failure of surface condenser tubes is a critical factor for its efficiency and lifetime. This pap...
Source
#1Nan Xu (Hohai University)H-Index: 11
#2Q.N. Song (Hohai University)H-Index: 5
Last. Yefeng Bao (Hohai University)H-Index: 10
view all 3 authors...
Abstract In this work, two-mm-thick C44300 tin brass plates were successfully joined by double-pass rapid cooling friction stir welding (RCFSW). The microstructure evolution of the welded joint was carefully studied by high resolution electron backscatter diffraction and transmission electron microscopy. The results showed that the heat-affected zone, which usually deteriorates the mechanical properties of the weld, was completely eliminated by using liquid CO2 for cooling. For single-pass RCFSW...
2 CitationsSource
#1Khalil Ranjbar (Shahid Chamran University of Ahvaz)H-Index: 10
#2A. Taghavian (Shahid Chamran University of Ahvaz)H-Index: 1
Last. M. Amra (Shahid Chamran University of Ahvaz)H-Index: 2
view all 3 authors...
Failure analysis of a tubular oil heat exchanger made up of admiralty brass in an industrial unit was investigated. In the oil exchanger, circulating water is used as a coolant inside the brass tubes to reduce the temperature of oil flowing inside the brass shell. The causes of failure of the leaked admiral tubes were investigated performing various visual and microscopic examinations. Chemical analysis of the corrosion scales and its phase analysis with x-ray diffraction and microstructural exa...
1 CitationsSource
#1Alireza KhalifehH-Index: 1
#1Alireza KhalifehH-Index: 1
4 CitationsSource
#1Willem Faes (UGent: Ghent University)H-Index: 2
#2Steven Lecompte (UGent: Ghent University)H-Index: 14
Last. Michel De Paepe (UGent: Ghent University)H-Index: 23
view all 7 authors...
In many industries and processes, heat exchangers are of vital importance as they are used to transfer heat from one fluid to another. These fluids can be corrosive to heat exchangers, which are usually made of metallic materials. This paper illustrates that corrosion is an important problem in the operation of heat exchangers in many environments, for which no straightforward answer exists. Corrosion failures of heat exchangers are common, and corrosion often involves high maintenance or repair...
12 CitationsSource