Ramakanta Jena
KIIT University
Static VAR compensatorAC powerTransmission systemOpen-loop controllerVoltagePower electronicsPower-flow studyVoltage regulationOscillationUnified power flow controllerThyristor switched capacitorThyristor controlled reactorComputer sciencePhotovoltaic systemVoltage optimisationFlexible AC transmission systemControl theoryMaximum power transfer theoremControl theoryElectric power system
15Publications
2H-index
20Citations
Publications 14
Newest
#1Ramakanta Jena (KIIT: KIIT University)H-Index: 2
#2Sarat Chandra Swain (KIIT: KIIT University)H-Index: 9
Last. Ritesh DashH-Index: 1
view all 4 authors...
Source
#1Ramakanta Jena (KIIT: KIIT University)H-Index: 2
Last. P. C. Panda (KIIT: KIIT University)H-Index: 4
view all 5 authors...
This work presents Arctic Char Algorithm (ACA) for solving optimal reactive power problem. In North America movement of Arctic char phenomenon is one among the twelve-monthly innate actions. Deeds of Arctic char have been imitated to design the algorithm. In stochastic mode solutions are initialized with one segment on every side of to the route ascendancy; particularly in between lower bound and upper bounds. Previous to the movement, Arctic char come to a decision about the passageway based on...
Source
#1Ganesh Prasad Khuntia (KIIT: KIIT University)H-Index: 1
#2Ramakanta Jena (KIIT: KIIT University)H-Index: 2
Last. Ritesh DashH-Index: 1
view all 4 authors...
Source
#1Ramakanta JenaH-Index: 2
Last. Ritesh DashH-Index: 1
view all 3 authors...
Source
#1Shaswat Chirantan (KIIT: KIIT University)H-Index: 2
#2Ramakanta Jena (KIIT: KIIT University)H-Index: 2
Last. P. C. Panda (KIIT: KIIT University)H-Index: 4
view all 4 authors...
Power system stability dilemma demonstrates the effect of generator electro-mechanical oscillations & rotor angle swings on electrical grids.Power System Stabilizers(PSS) is an excitation controller used to damp out the generator electromechanical oscillations & rotor angle swings.But in severe faulted condition PSS cannot damped out the oscillations alone such as in case of a LLL-G fault.So in order to make the system stable by damping generator oscillations & rotor angle swings FACTS controlle...
Source
#1S. C. Swain (KIIT: KIIT University)H-Index: 2
#2Ramakanta Jena (KIIT: KIIT University)H-Index: 2
Last. P. C. Panda (KIIT: KIIT University)H-Index: 4
view all 4 authors...
The Controlled Reactive Power Gives the Desired Optimal flow of Power in the line. The FACTS devices effectively control the flow of Power in the lines. Improvement of voltage profile and minimization of losses are studied here with Optimal and non- Optimal Power Flow. The effectiveness and suitability of UPFC controllers are being discussed and is demonstrated through an Example and is clear that this device has the capability of regulating the flow of power, minimization of power losses.
Source
#1Ramakanta Jena (KIIT: KIIT University)H-Index: 2
#2Shaswat Chirantan (KIIT: KIIT University)H-Index: 2
Last. P. C. Panda (KIIT: KIIT University)H-Index: 4
view all 4 authors...
The demand of quality & reliable power by the consumers is increasing day by day in a tremendous manner. Everyone needs good quality of power with out any disturbances or interruptions. Also due to large no of present day consumers, the power system needs a boosting mechanism in order to capitalize the complexity of power system. So a reliable technology of FACTS(Flexible AC Transmission System) is introduced in the power system to enhance the flexibility of power grids. FACTS devices are power ...
4 CitationsSource
#1Shaswat Chirantan (KIIT: KIIT University)H-Index: 2
#2Ramakanta Jena (KIIT: KIIT University)H-Index: 2
Last. P. C. Panda (KIIT: KIIT University)H-Index: 4
view all 4 authors...
SVC(Static Var Compensator) is a shunt connected FACTS(Flexible AC Transmission System) controller consists of TCR(Thyristor Controlled Reactor), TSC(Thyristor Switched Capacitor) & filter elements for reactive power compensation. In this paper extended version of SVC representation by synchronizing the step down transformer reactance & overall SVC reactance. SVC reactance contains capacitive reactance of shunt capacitor and TCR reactance. Thus this model is termed as Integrated Transformer Firi...
2 CitationsSource
#1Shaswat Chirantan (KIIT: KIIT University)H-Index: 2
#2Sarat Chandra Swain (KIIT: KIIT University)H-Index: 9
Last. Ramakanta Jena (KIIT: KIIT University)H-Index: 2
view all 4 authors...
This paper represents the modeling and simulation of various FACTS devices like static var compensator(SFC), static synchronous compensator(STATCOM), thyristor controlled series capacitor(TCSC), static synchronous series compensator, (SSSC) and unified power flow controller(UPFC). Also thereby analyzed the performance of such devices for improvement of power transfer capability and real & reactive power compensation. Here the flow of real and reactive power have been studies by the implementatio...
5 CitationsSource
#1Shaswat Chirantan (KIIT: KIIT University)H-Index: 2
#2Ramakanta Jena (KIIT: KIIT University)H-Index: 2
Last. P. C. Panda (KIIT: KIIT University)H-Index: 4
view all 4 authors...
In recent power system scenario, the main concern is about the maximum power transfer capability from generating station to the distribution station. But between these, the transmission system i.e. transmission of power from generating station to distribution grid is the most vital thing. So in order to have a reliable and quality power transmission FACTS controllers (Flexible AC Transmission System) are introduced in the transmission system. FACTS is an emerging technology which motivates towar...
2 CitationsSource
12
Close Researchers