Facundo Almeraya
PhysicsCuring (chemistry)HumanitiesComposite materialAbsorption of waterFlexural strengthIntergranular corrosionMetallurgyMaterials scienceMineralogyCorrosionElectrochemical noiseStress corrosion crackingCarbonatationCharacterization (materials science)ThermoplasticReinforced concreteCompressive loadSystem aConcrete beamsCorrosion potentialSalt waterHigh strain ratePassivationChemical engineeringAluminiumCementElectrochemistryFiber-reinforced compositeCrackingPlasticizerTernary operationPorosityDielectric spectroscopyForensic engineeringFly ash
14Publications
1H-index
5Citations
Publications 14
Newest
#1Carolina RamirezH-Index: 1
#2Vitor Luiz ReisH-Index: 2
Last. Miguel BaltazarH-Index: 2
view all 9 authors...
1 CitationsSource
#2Facundo AlmerayaH-Index: 1
Last. Alberto MartínezH-Index: 4
view all 5 authors...
En este trabajo de investigacion se establece un sistema de conservacion de puentes de concreto reforzado, a traves de un monitoreo autonomo a distancia, instalando sensores de corrosion y transmitiendo las senales por radio modem de manera inalambrica en tiempo real, con la finalidad de corregir oportunamente los danos causados por la corrosion en ambientes marinos. El estudio se basa en una evaluacion y diagnostico completos de puentes empleando tecnicas de Mapeo de Potenciales de Corrosion (A...
#1Ricardo Velásquez (Grupo México)
#2María Acosta (Grupo México)
Last. Alberto Martínez (Grupo México)H-Index: 4
view all 5 authors...
En este trabajo se busco determinar la influencia de los aditivos en la corrosion de estructuras de concreto reforzado, empleando tecnicas electroquimicas.Se hizo la determinacion cuantitativa y cualitativa de sus propiedades (analisis quimico de aditivos, acero, pH, resistencia a compresion, flexion, porosidady absorcion), de las cantidades optimas de acuerdo a las Normas ASTM y ACI. Se evaluo el desempeno de los aditivos, se midieron potenciales yvelocidades de corrosion. Tambien se determino ...
#1María Acosta (Grupo México)
#2Ricardo Velásquez (Grupo México)
Last. Alberto Martínez (Grupo México)H-Index: 4
view all 5 authors...
La presente investigacion tuvo como objetivo principal evaluar el comportamiento de corrosion en vigas de concreto reforzado, por medio tecnicas electroquimicas como la medicion de Potenciales de Corrosion y Resistencia a la Polarizacion Lineal. Estas vigas son expuestas a ciclos de secado y saturacion en agua potable y cloruro de sodio (NaCl) al 3.5%, ya que la tecnica de Resistencia a la Polarizacion es la que actualmente se aplica para la evaluacion de estructuras de concreto reforzado asi co...
view all 6 authors...
Source
#1J. L. PérezH-Index: 7
#2Citlalli GaonaH-Index: 3
Last. Leonel LópezH-Index: 1
view all 6 authors...
In this work, corrosion of reinforcing steel in concrete beams exposed to two environments was evaluated. The two environments used were: drinking water (white) and salt water (5% NaCl sol.) for 18-months. The concrete had a water/cement ratio of 0.40 and 0.60, respectively. Monitoring was carried out by measuring macrocell voltage and current, with open-circuit potentials and electrochemical noise. The results presented more probability of corrosion in beams immersed in salt water with higher w...
1 CitationsSource
#1Miguel BaltazarH-Index: 2
#2Facundo AlmerayaH-Index: 1
Last. Arturo OrtizH-Index: 1
view all 6 authors...
It’s evaluated the corrosion of 304 stainless steel and steel 1018, embedded in elaborated specimens of concrete on the basis of norms ASTM C470-87 and C192-81. Were elaborated concrete of ration a/c, 0,45 and 0.65 . The specimens were exposed 66 weeks in two aggressive means, solutions to 3,5% of NaCl and 3,5% of Na2SO4. The evaluation was made by the technique of Resistance to the Polarization (Rp), measurement of the corrosion potential (Ecorr) in agreement norm ASTM C-876-91. The results far...
2 CitationsSource
#1Abraham LópezH-Index: 1
#2Facundo AlmerayaH-Index: 1
Last. Víctor OrozcoH-Index: 1
view all 5 authors...
The effect of three curing methods (immersion, waterproof membrane and steam) in the corrosion rate of reinforced concrete beams, w/c ratio of 0.40 and cover thickness of 4 cm, are exposed in synthetic water (ASTM 1141-98) during a total of 180 days. The corrosion rates are obtained by linear polarization (LPR) and electrochemical impedance spectroscopy (EIS). According to the obtained results, curing methods that they maintain a mayor time the wet state in the concrete have a best performance i...
1 CitationsSource
#2Facundo AlmerayaH-Index: 1
Last. Miguel BaltazarH-Index: 2
view all 5 authors...
Se estudiaron concretos adicionando ceniza volante, micro-silice y escoria de alto horno, el objetivo fue determinar cual de las mezclas presenta mejor comportamiento como proteccion contra la corrosion del acero. Se prepararon seis mezclas y se construyeron celdas de concreto donde se le adiciono el 20% con respecto al peso de aditivos, con dos varillas embebidas en la mezcla como electrodos y fueron expuestas a una solucion de NaCl (3.5% en peso), durante ocho meses se monitorearon con tecnica...
Source
#1Facundo AlmerayaH-Index: 1
Last. Alberto MartínezH-Index: 4
view all 5 authors...