Youngsub Eom
Korea University
OphthalmologySurgeryPathologyChemistryKeratometerDioptreCataract surgeryCorneaMeibomian glandVisual acuityTearsAstigmatismIntraocular lensIntraocular lens power calculationPhacoemulsificationEyelidMeibomian gland dysfunctionIntraocular lensesIn patientOcular surfaceMedicine
105Publications
16H-index
721Citations
Publications 110
Newest
#1Tae Joon Jun (Asan Medical Center)H-Index: 5
#2Youngsub Eom (KU: Korea University)H-Index: 16
Last. Daeyoung Kim (KAIST)H-Index: 31
view all 8 authors...
Abstract In this paper, we proposed Transferable Ranking Convolutional Neural Network (TRk-CNN) that can be effectively applied when the classes of images to be classified show a high correlation with each other. The multi-class classification method based on the softmax function, which is generally used, is not effective in this case because the inter-class relationship is ignored. Although there is a Ranking-CNN that takes into account the ordinal classes, it cannot reflect the inter-class rel...
Source
Source
#1Youngsub Eom (KU: Korea University)H-Index: 16
#2Soomi KimH-Index: 2
Last. Hyo Myung Kim (KU: Korea University)H-Index: 19
view all 0 authors...
Self-sealing hyaluronic acid (HA)-coated self-sealing 30-gauge needles exhibiting instant leakage prevention of intravitreal humor and injected drug were developed in this study. Ninety New Zealand rabbits were used in this study. We assessed dye regurgitation in intravitreal ICG dye injections using HA-coated needles (HA needle group) and conventional needles (control group). Vitreous humor levels of anti-vascular endothelial growth factor (VEGF) were compared between groups one, three, and sev...
Source
#1Jung Wan KimH-Index: 8
#2Youngsub Eom (KU: Korea University)H-Index: 16
Last. Hyo Myung Kim (KU: Korea University)H-Index: 19
view all 8 authors...
Purpose null To compare the prediction accuracy of algorithmic intraocular lens (IOL) power calculation formula selection method using conventional formulas (Haigis, Hoffer Q, Holladay 1, SRK/T and/or Barrett Universal II) based on keratometry (K), anterior chamber depth (ACD) and axial length (AL). null Methods null A total of 1653 patients (1653 eyes) implanted with Tecnis ZCB00 IOL during cataract surgery were enrolled in this study. Intraocular lens (IOL) power calculation formulas with a sm...
Source
#1Jungah Huh (KU: Korea University)H-Index: 2
#2Youngsub Eom (KU: Korea University)H-Index: 16
Last. Hyo Myung Kim (KU: Korea University)H-Index: 19
view all 6 authors...
To evaluate the prediction accuracy of the intraocular lens (IOL) power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio in the Haigis formula (Haigis-E) in patients with a history of prior myopic laser vision correction. Seventy eyes from 70 cataract patients who underwent cataract surgery and had a history of myopic laser vision correction were enrolled. The adjusted corneal power obtained with conventional keratometry (K) was calculate...
1 CitationsSource
#1Young S. Choi (KU: Korea University)H-Index: 20
#2Youngsub Eom (KU: Korea University)H-Index: 16
Last. Hyo Myung KimH-Index: 19
view all 6 authors...
PURPOSE The purpose of this study was to evaluate the efficacy of topical ivermectin 1% cream application on the eyelashes in combination with eyelid hygiene in the treatment of Demodex blepharitis. METHODS One hundred two eyes of 102 patients with symptomatic Demodex blepharitis were divided into 2 groups according to the use of topical ivermectin in this retrospective case-control study. The ivermectin group (n = 51) applied topical ivermectin 1% cream on the eyelashes for 15 minutes once week...
Source
#1Soonil Koun (KU: Korea University)H-Index: 2
#2Youngsub Eom (KU: Korea University)H-Index: 16
Last. Hyo Myung Kim (KU: Korea University)H-Index: 19
view all 8 authors...
Abstract Background To investigate the efficacy of a novel experimental model for exploring visual function using a contrast-optomotor response (C-OMR) assay made by applying the contrast sensitivity test to the OMR assay in zebrafish. Methods Zebrafish larvae were treated with 0 (control), 5, 10, or 15 μM gentamicin and digoxin for 24 h at four days post-fertilization (dpf). Zebrafish larvae were assessed using the C-OMR assay with graded contrast gray-white stripes at 5 dpf, and the results we...
Source
#1Jung Wan KimH-Index: 8
#2Youngsub Eom (KU: Korea University)H-Index: 16
Last. Hyo Myung Kim (KU: Korea University)H-Index: 19
view all 8 authors...
Abstract Purpose To investigate the early incidence of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy according to intraocular lens (IOL) type (non-toric vs. toric) and surgical techniques (femtosecond laser-assisted cataract surgery vs. conventional phacoemulsification) in eyes with refractive multifocal IOLs. Design Retrospective case-control study. Methods Nine hundred thirteen eyes from 483 patients implanted with Lentis Mplus LS-313 MF20 (771 eyes) or Lentis Mplus Toric ...
1 CitationsSource
#1Youngsub Eom (KU: Korea University)H-Index: 16
#2Joon Young Hyon (Seoul National University Bundang Hospital)H-Index: 22
Last. Hyo Myung Kim (KU: Korea University)H-Index: 19
view all 5 authors...
PURPOSE To compare the proportions of patients satisfying Korean dry eye guidelines and Asia Dry Eye Society (ADES) diagnostic criteria and to describe the clinical characteristics and practice patterns of dry eye patients in Korea. STUDY DESIGN Prospective observational study. METHODS This study enrolled 160 patients, with 158 patients analyzed. ADES guidelines were applied to dry eye patients satisfying the Korean dry eye guidelines. Risk factors for dry eye (e.g. visual display terminal [VDT]...
Source
Source