Andrea Natale
Scripps Health
Internal medicineRadiologySurgeryCardiologyRandomized controlled trialCatheter ablationVentricular tachycardiaRadiofrequency ablationHeart failureAblationAtrial fibrillationPulmonary veinCatheterPopulationLeft atrialIn patientAnesthesiaStrokeMedicineEjection fraction
1,309Publications
118H-index
46.6kCitations
Publications 1336
Newest
Background: Optimal duration of energy delivery in high-power short-duration (HPSD) ablation to create a durable lesion in atrial fibrillation (AF) is not clear yet. We evaluated the association of...
Source
#1Alessio GasperettiH-Index: 10
#2Marco SchiavoneH-Index: 6
Last. Matteo Ziacchi (UNIBO: University of Bologna)H-Index: 21
view all 14 authors...
INTRODUCTION The PRAETORIAN score (PS) was developed to assess the implant position and predict defibrillation success of the subcutaneous implantable cardioverter defibrillators (S-ICD). The main critique moved to the routine use of PS has been its postprocedural timing, that limits its usefulness on procedure guidance. The aim of this proof-of-concept study was to assess the feasibility of an intraprocedural use of PS. METHODS Forty consecutive patients undergoing S-ICD implantation were enrol...
Source
#1Sanjeev SaksenaH-Index: 19
#2April SleeH-Index: 1
Last. Pasquale Santangeli (HUP: Hospital of the University of Pennsylvania)H-Index: 62
view all 7 authors...
Aims: We studied the impact of atrial fibrillation (AF) presentation on total & cause-specific cardiovascular (CV) mortality & hospitalizations (H) in mild & advanced heart failure (HF) strata as well as HF worsening in the TOPCAT AMERICAS study. Methods: We analyzed 1765 subjects with HF & preserved ejection fraction (pEF) and AF with two AF different presentations at entry: a) Any AF event (remote or ongoing, n=760), to those without any such AF events (n=1005) and b) Ongoing AF on ECG at enro...
#1Amin Al-AhmadH-Index: 21
#2Bradley P. Knight (NU: Northwestern University)H-Index: 68
Last. G. Joseph GallinghouseH-Index: 31
view all 13 authors...
BACKGROUND Intracardiac electrogram data remain one of the primary diagnostic inputs guiding complex ablation procedures. However, the technology to collect, process, and display intracardiac signals has known shortcomings and has not advanced in several decades. OBJECTIVE The purpose of this study was to evaluate a new signal processing platform, the PURE EP™ system (PURE), in a multi-center, prospective study. METHODS Intracardiac signal data of clinical interest were collected from 51 patient...
Source
#1Antonio Russo (Marche Polytechnic University)H-Index: 102
#2Paolo Compagnucci (Marche Polytechnic University)H-Index: 4
Last. Giulia Stronati (Marche Polytechnic University)H-Index: 3
view all 21 authors...
Background null Ventricular arrhythmias (VAs) represent a critical issue with regard to sports eligibility assessment in athletes. The ideal diagnostic evaluation of competitive and leisure-time athletes with complex VAs has not been clearly defined. null null null Objective null The purpose of this study was to assess the clinical implications of invasive electrophysiological assessments and endomyocardial biopsy (EMB) among athletes with VAs. null null null Methods null We evaluated 227 consec...
1 CitationsSource
#1Jalaj Garg (MCW: Medical College of Wisconsin)H-Index: 19
#2Kuldeep Shah (Oakland University)H-Index: 7
Last. Dhanunjaya LakkireddyH-Index: 49
view all 5 authors...
Source
#1Ranjan K. Thakur (MSU: Michigan State University)H-Index: 19
#2Andrea NataleH-Index: 118
Source
#1Jalaj Garg (LLU: Loma Linda University)
#2Siddharth Shah (State University of New York Upstate Medical University)H-Index: 7
Last. Dhanunjaya LakkireddyH-Index: 49
view all 6 authors...
Source
#1Luigi Di Biase (Albert Einstein College of Medicine)H-Index: 77
#2Jorge Romero (Albert Einstein College of Medicine)H-Index: 23
Last. Andrea NataleH-Index: 118
view all 18 authors...
Background Direct oral anticoagulants (DOACs) are contraindicated in patients with atrial fibrillation (AF) and mechanical cardiac valves. However, safety and efficacy are controversial in patients with biological cardiac valves. Objective We report the safety and feasibility of periprocedural and long-term treatment with DOACs in patients with biological valves undergoing ablation for AF. Methods A total of 127 patients with AF and biological cardiac valve undergoing CA on uninterrupted DOAC we...
1 CitationsSource
Source