V. Del Marmol
Université libre de Bruxelles
EpidemiologyInternal medicineConfocalPublic healthSurgeryCross-sectional studyPathologyOncologyDermatologyIntensive care medicineImmunologyPsychological interventionHidradenitis suppurativaMelanomaSkin cancerActinic keratosisBasal cell carcinomaOptical coherence tomographyNevusMEDLINEPopulationReticular DermisSkin Cancer PreventionPan europeanIncidence (epidemiology)Family medicineBiochemistryMedicineEnvironmental health
102Publications
21H-index
1,443Citations
Publications 102
Newest
#1Elisa Cinotti (UNISI: University of Siena)H-Index: 18
#2Linda Tognetti (UNISI: University of Siena)H-Index: 11
Last. M. Fontaine (ULB: Université libre de Bruxelles)H-Index: 3
view all 0 authors...
BACKGROUND Early and accurate diagnosis of cutaneous squamous cell carcinoma (SCC) and actinic keratosis (AK) is fundamental to reduce their morbidity and to select the correct treatment. Line-field confocal optical coherence tomography (LC-OCT) is a new imaging device that can characterize healthy skin and basal cell carcinoma, but no large studies are available on keratinocyte cell tumours. OBJECTIVES To identify and describe LC-OCT criteria associated with SCC and AK and to compare LC-OCT fin...
Source
#1Mariano Suppa (ULB: Université libre de Bruxelles)H-Index: 15
#2M. Fontaine (ULB: Université libre de Bruxelles)H-Index: 3
Last. V. Del Marmol (ULB: Université libre de Bruxelles)H-Index: 21
view all 19 authors...
BACKGROUND Early diagnosis and subtype classification of basal cell carcinoma (BCC) are crucial to reduce morbidity and optimize treatment. Good accuracy in differentiating BCC from clinical imitators has been achieved with existing diagnostic strategies but lower performance in discriminating BCC subtypes. Line-field confocal optical coherence tomography (LC-OCT) is a new technology able to combine the technical advantages of reflectance confocal microscopy and OCT. OBJECTIVES To identify and d...
2 CitationsSource
#1Mathieu Daoud (ULB: Université libre de Bruxelles)H-Index: 1
#2Hassane Njimi (ULB: Université libre de Bruxelles)H-Index: 9
Last. V. Del Marmol (ULB: Université libre de Bruxelles)H-Index: 21
view all 9 authors...
Source
#1M. Daxhelet (ULB: Université libre de Bruxelles)H-Index: 3
#2Mathieu Daoud (ULB: Université libre de Bruxelles)H-Index: 1
Last. V. Del MarmolH-Index: 21
view all 9 authors...
Source
#1Clément Lenoir (ULB: Université libre de Bruxelles)
#1C. Lenoir (ULB: Université libre de Bruxelles)
Last. Mariano Suppa (ULB: Université libre de Bruxelles)H-Index: 15
view all 15 authors...
Line-field confocal optical coherence tomography (LC-OCT) is a newly developed non-invasive imaging technique that combines high penetration depth (500 µm, similar to conventional OCT) with high isotropic resolution (lateral 1.3 µm, axial 1.1 µm, similar to reflectance confocal microscopy [RCM]).1 Moreover, with its ability to produce images in both vertical and horizontal planes, it enables a tridimensional (3D) analysis of the skin, which can prove very useful for assessing physiological2 as w...
Source
#1C. Lenoir (ULB: Université libre de Bruxelles)
#2Javiera Pérez-Anker (University of Barcelona)H-Index: 5
Last. Mariano Suppa (ULB: Université libre de Bruxelles)H-Index: 15
view all 12 authors...
Line-field confocal optical coherence tomography (LC-OCT) is a recently developed non-invasive imaging technique able to combine the technical principles of conventional OCT (high in-tissue penetration and visualization of the vertical plane) and reflectance confocal microscopy (high resolution).1-3 Indeed, LC-OCT provides tridimensional images of the skin (vertical and horizontal planes) up to a 500-µm depth and features excellent isotropic resolution (lateral: 1.3 µm; axial: 1.1 µm).
Source
#1J. Monnier (AMU: Aix-Marseille University)H-Index: 9
#2Linda Tognetti (UNISI: University of Siena)H-Index: 11
Last. J.-L. PerrotH-Index: 10
view all 15 authors...
Introduction Les differentes structures de la peau peuvent etre maintenant etudiees in vivo en fonction de la topographie grâce a la tomographie confocale a coherence optique en ligne (LC-OCT, DAMAE Medical®, Paris, France). Cette nouvelle technologie optique d’imagerie cutanee non-invasive innovante permet la visualisation in vivo en temps reel de la peau en coupe verticale, similaire a l’histologie, de haute resolution a un niveau cellulaire (resolution spatiale isotrope ∼1 μm et profondeur de...
Source
#1J. Monnier (AMU: Aix-Marseille University)H-Index: 9
#2J. Perez (University of Barcelona)H-Index: 1
Last. Joseph Malvehy (University of Barcelona)H-Index: 25
view all 11 authors...
Introduction La line-field optical coherence tomography (LC-OCT) est une nouvelle technique d’imagerie cutanee non invasive, innovante, permettant d’obtenir des images 3D, a resolution cellulaire, sur une profondeur de ∼500 μm. Son role dans l’aide au diagnostic in vivo du melanome n’a pas encore ete etabli. L’objectif de cette etude est d’identifier et decrire les caracteristiques en LC-OCT 3D des melanomes et les comparer a celles des principaux types de naevus. Materiel et methodes Des patien...
Source
#1Mariano SuppaH-Index: 15
#2M. FontaineH-Index: 3
Last. J.-L. PerrotH-Index: 10
view all 19 authors...
Introduction Le diagnostic precoce et la classification par sous-type du carcinome basocellulaire (CBC) sont essentiels pour reduire la morbidite et optimiser le traitement. Les strategies actuelles de diagnostic (dermatoscopie et microscopie confocale) ont permis d’obtenir une bonne precision dans la differenciation du CBC des imitateurs cliniques, mais elles sont moins performantes dans la discrimination des sous-types de CBC. La tomographie confocale a coherence optique en ligne (LC-OCT, DAMA...
Source
Introduction La jonction dermo-epidermique (JDE) n’est pas similaire sur l’ensemble des differentes parties du corps a l’instar des autres constituant de la peau, du fait d’une specialisation liee a la topographie et a la fonctionnalite attenante. La JDE a ete evaluee initialement ex vivo au moyen des coupes histologiques, puis in vivo en microscopie confocale. Dans les 2 cas il s’agissait d’imagerie 2 D alors que la JDE est une structure complexe tridimensionnelle. Or la nature de la JDE n’est ...
Source